A And D Pulse Ambulatory BP Monitor , BP Meters For Hospital
Negotiable /Piece
Min.Order:1 Piece
Zhejiang Formegga Health Technology Co.Ltd
Talking Electronic Blood Pressure Monitors Professional And Upper Arm
24 Hour Digital Upper Arm BPM , Aneroid Blood Pressure Monitor Machine
Digital Electronic Blood Pressure Monitors Accuracy Automatic
Digital Accurate Blood Pressure Monitor Upper Arm with Automatic inflate and deflate
Upper Arm Accurate Blood Pressure Monitor , Electronic and aneroid
A and D pulse Accurate Blood Pressure Monitor for hospital / home
A And D Pulse Ambulatory BP Monitor , BP Meters For Hospital
Specifications:
1. Model Number: ML-8010
2. Type: arm / Upper Arm
3. Display backlight
4. Display: 68 x 79mm (Liquid Crystal Display) LCD Digital Display
5. Memory: 2*60 sets for 2 users
6. Functions:with Voice, with LCD display; With Stethoscope, with talking, Automatically inflate and deflate, Automatic power-off function, Year/month/date/time function
7. Features: Electronic, digital, automatic
8. Measurement Range: Pressure: 0~280mmHg, Pulse: 40~199 times/min
9. Size: 126*120*160 mm
10 Power supply: 6V DC (4 \"AA\" batteries)
11. Accuracy: ±0.4kPa
12. Operating air pressure: 860hPa~1060hPa
13. Usage: Household, Hospital
14. Inflation: Automatic Inflation
15. Deflation: Automatic exhaust
16. Measuring Method: Oscillometric Measurement
Description:
1.Double use, each 60 groups of automatic memory
2.Date/Time Set function
3.Indicating average of the latest 3 readings
4.Large LCD display
5.Voice broadcast
6.Alarm clock function
7.High pressure alarm
8.Low battery warning
9.60 sec auto off
10.Intelligent control measurement techniques
Applications:
Take a measurement one hour later after a meal. One hour before measurement, please don\'t smoke, drink alcohol, tea or coffee If Over fatigue or emotional instability, please don’t measure. 10-20minutes before measurement, keep quite state. As far as possible, every day in the same time and conditions, with same posture, 5 minutes interval between measurements. If stored in low temperature environment, before using, first should put it in normal temperature environment place for at least one hour. Do not use it in mobile vehicles (cars, planes), otherwise can\'t correctly measure. Please use it according to the instruction of temperature and humidity standard, or it may not be able to correctly measure; If the air bag is over inflated, there may be risk. When common arrhythmia (such as atrial premature, premature ventricular, atrial fibrillation) appears, measured values may not accurate or blood pressure can\'t be measured.Competitive Advantage:
1, 60 groups memories, 120 memories totally
2, liner discharge valve
3, AVX Tantalum capacitor
4, Mainly parts are from Japan
Specifications:
Brand Name |
Formegga |
Model Number |
ML-8010 |
Measurement Type |
Oscillography |
Material |
ABS+ |
Voltage |
6V |
Brand |
Formegga |
Color |
white or as per customer\'s design |
FOB Port |
Shanghai |
Payment Terms |
L/C T/T |
Gift box size |
17.6x14x14.2cm |
Carton size |
54.5*29.5*30 cm |
Battery |
AA 4pcs |
Voice |
Yes |
Back light |
Yes |
Cuff Size |
22--36cm |