BJH pore size distribution measurement apparatus
BJH pore size distribution measurement apparatus
BJH pore size distribution measurement apparatus

BJH pore size distribution measurement apparatus

USD $19800 - $19800 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
GAPP
Place of Origin:
China
Model Number:
V-Sorb 2800P

Gold APP Instruments Corporation China

Business Type: Trading Company
Main Products: surface area and pore size analyzer , true density analyzer , high pressure volumetric analyzer , degasser

Product Details

V-Sorb 2800P surface area and pore size distribution analyzer introduction

V-Sorb 2800P is Gold APP self-developed surface area and porosity analyzer which utilizes static volumetric. Compared with other companies analyzers, multi pioneered techs make instrument’s performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in domestic competitors and partial applications surpass foreign instruments. Products designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands.

V-Sorb 2800P surface area and pore size distribution analyzer parameters

Analysis Method
: static volumetric nitrogen adsorption

Versatility: Adsorption and desorption isothermal curve analysis, Single and multi point BET method specific surface area analysis, Langmuir method specific surface area analysis, Average particle diameter estimation, T-plot method external surface area analysis, True density analysis, BJH total pore volume and pore size distribution analysis, T-plot method micropore analysis, MP method micropore analysis, HK method micropore analysis

Measuring Ranges: 0.01m2/g to no known upper limit(specific surface area); 0.35 to 400nm (pore size)

Accuracy: repeatability errors ≤1.5%

Vacuum System: V-sorb unique assembling-installed manifolds and electromagnetically operated valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Controller: V-sorb original coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night

Control System: programmable controller electromagnetically operated valve system with high integration and strong anti-interference ability, enhance instrument’s stability and life

Sample Ports: two samples analyzing and two samples degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)

Transducer Accuracy: imported silicon thin film transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.995

 

V-Sorb 2800P surface area and pore size distribution analyzer features

A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2.Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

 

B: Control System

1. Industry used programmable controller electromagnetically operated valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

 

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

Visit for more.

Contact Supplier

GoldAPP Instruments Chat Now
Telephone
86-10-82132122
Mobile
86-18210009838
Fax
86-10-82118197
Skype
Gold-APP-Instruments
Address
Floor 6th, Tianli Building, No. 56th, Zhichun Rd., Haidian Dist, Beijing 100098 Liaocheng,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > Gas Analyzers
Categories
Hi~