Offer aidu AD-3530AA Atomic Absorption Spectrophotometer
USD $1 - $1
Min.Order:1
Shanghai Aidu Energy Science Co. Ltd.
high precision with high efficiency
element analyzer,ore analyzer, alloy analyzer, portable element analyzer , chemical analysis method,atomic absorption analyzer,high sensitivity multi-element analyzer,mine composition analyzer,mine elements analyzer,composition elements analyzer,gold tester,multi-element analyzer etc.
We are one of largest professional and reliable manufacturers of geophysical survey and geophysical prospecting, such as geophysical prospector, resistivity meter, VLF system, electrical prospecting, high density prospecting instrument, groundwater detector, mineral prospector, ore detector, gold detector,water locator,resistivity imaging survey, electromagnetic system equipment, electrical resistance, resistivity IP and SP system, resistivity, TEM survey, TEM system, EM system,magnetometer, radioactive detector, seismograph, gravity meter, logging system,proton magnetometer, drill equipment, drill rig, well drilling equipment, core drilling equipment, hydraulic drill equipment, and element analyzer.
Feature:
Unique full reflection optical system
D-lamp background correction
High resolution and exact peak seeking ability
3 Atomic temperature rise mode
Unique design automatic 8 lamps holder system
Steady flow full titanium burner
Intelligence control function
General safety precautions
Window2000/XP conciseness, professional, automatic, full operation SP Win-AAS software
QA/QC function
Full information measurement
Main Parameter:
Optical System
• Instrument Type Single Beam Reflection Achromatic Optics System
• Monochrometer: Achromatic C-T
• Bandwidth(nm):0.1,0.2,0.7,1.4nm Adjustable
• Wavelength Range (nm):190-900
• Wavelength Accuracy (nm):±0.20
• Wavelength Repeatability(nm):≤0.10
• Resolution better than 0.3nm (Mn279.5nm and 279.8nm peak valley≤30%)
Spectrophotometric Properties:
• Measurement: A.T.C
• Photometric Range:0-125%,-0.1-3.00A
• Static Baseline Drift (Cu):±0.003A/30min
• Dynamic Baseline Drift (Cu):±0.004A/30min
• Background Correction: D-lamp background correction,Self-absorbance background correction >50times correction ability (1Abs)
• Atomization System: Flame + graphite furnace
Flame:
• Characteristic Concentration:(Cu)≤0.03ug/mL/1%
• Detection limit:(Cu)≤0.006ug/mL
• Precision:RSD≤1%
• Burner:titanium
• Nebulizer:hight-efficient glass nebulizer
• Spray chamber:anticorrosion material
• Safety measures:Flame fuel gas, power assisted gas abnormal pressure protection
Graphite Furnace
• Characteristic quantity Characteristic value: Cd≤0.5×10-12g
• Detection Limit Characteristic value: Cd≤1.0×10-12g
• Precision Precision: Cd≤3%
• Test Manner :Flame, Graphite Furnace, hydride-AA, flame emission
Data Process
• Concentration:Standard curve, standard addition, interpolation
• Times of repetitive Measurement:1-30times,Average value of A&C
• QA/QC:relative coefficient,Abs. concentration SD,RSD,Analysis data electronic document export is feasible.
• data output:Test data could be saved as original record form through Pro-software
• report print:parameters, data result, graph
• data interface:Standard RS-232 interface
Instrument function
• Instrument setup D-lamp background correction auto-adjust optics beam device
• Automatic wavelength scan, peak seeking band width adjust
• Automatic ignite adjust negative high voltage
• lamp current, balance two beams, flameout protection
If you are interested in , please feel free contact Miss Season
E-mail:aiduseason(dot)9896(at)yahoo(dot)cn
MSN:season_zhao88(at)msn(dot)cn
Skype:Season15781
Mobile:086-18019477897 or 086+15221168650