Optical Digital Relay Test System , 50Hz / 220V / 850nm KF900
Negotiable /Piece
Min.Order:1 Piece
50Hz / 220V Relay Test System , 50 / 51 Overcurrent Test K3066Li
Parameter Conversion KRT Relay Testing Software Module Database
High Reliability Protection Relay Testing Secondary Injection K3063+
4 Phase AC Protection Relay Testing , 10 Output Channels K3063i
250V / 3A Protection Relay Testing K3066 , 7 Phase AC ( L-N )
Optical Digital Relay Test System , 50Hz / 220V / 850nm KF900
1.Easy test
2.operation menu, Simple operation
3.IEC60044-7/8 standard
4.Wave Length:850nm
* With four fiber Ethernet interfaces and 3-way FT3 dedicated output interface
* In accordance with IEC61850-9-1 or IEC61850-9-2 frame format and send samples FT3 frame format or publish / subscribe GOOSE messages,
*The output sample value or GOOSE can be freely defined,
* Has 12 channels of analog output of weak signal, to achieve a variety of protection relay, monitoring and control devices, intelligent operation box testing.
Function Features
Provide fully test solutions to various IEC61850 relay protective devices & automation devices for all power users.
Provide 4 pairs of 100Base-FX optical interface, 3(FT3)ST optical out, support EC61850-9-1, EC61850-9-2, EC6004-7/8(FT3)and Goose optical digital message output test
Conventional analog binary input procession is compatible, providing 8 pairs analog binary input & 4 pairs binary output
Provide 1 RG-B/PPS interface, can access RG-B or PPS time signal which synchronize with GPS synchronous clock.
Technical Parameter
Binary Input |
|
No. |
8 pairs |
Input Characteristic |
0V~250V(DC) or no contanct (identified automatically) |
sample Frequency |
10kHz |
Time Resolution |
100μs |
Max measuring time |
1.50×105 s |
Timing Error |
±1ms (0.001s~1s) ±0.1%(1s~1.50×105 s) |
Set Range of Debounce Time( set by software) |
0ms~25ms |
Electric Isolation |
8 pairs input electric isolation |
Threshold Impedance Parameter(no contacts) |
5 kΩ…13kΩ |
Sychronization Interface (GPS) |
|
KSGGPS satellite sychronization device)is optional; B code (RS485) sychronization interface |
|
Binary Output |
|
No. |
4 pairs |
Type |
no contants and no pole, controlled by software |
AC capacity |
Vmax:250V (DC)/Imax:3A |
DC capacity |
Vmax:250V (DC)/Imax:1A |
Power Supply |
|
Rated Voltage |
220V(AC) |
Allowed Voltage |
100V~240V(AC) |
Rated Frequency |
50Hz |
Allowed Frequency |
40~60Hz |
Current |
1A (max.) |
FT3 Interface |
|
Using Standard |
IEC60044-7/8 |
Terminal NO. |
3 pairs |
Interface Type |
ST |
Wave Length |
850nm |
Optical Fiber Type |
62.5/125μm, multi-mode |
Transmission Distance |
1km |
Ethernet Communication Interface |
|
Type |