Oscilloscopes are used in the sciences, medicine, engineering, telecommunications, and industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system, or to display the waveform of the heartbeat as an electrocardiogram.
Humanness Functions: | |||
In order to protect the buttons and knobs on the instrument panel, avoid dust when storing. the instrument adds protection mask. | The instrument designs the storage container storing manual and accessories, more convenient to users. |
- Easy to read with color or monochrome (NST) LCD display
- Dual channel,Bandwith 25 - 200MHz
- Sample Rate(Real - time)500MHz up to 1GSa/s,Equivalent Sampling 50GSa/s.
- 4K channel memory depth.
- Advanced Triggering function from edge,video,pulse,delay.
- + - × ÷ Mathematic Functions
- FFT spectrum analysis:Hanning,Hamming,Blacking,Rectangle
-
Automatic Parameter Measurements:Vpp,Vamp,Vrms,Vmax,Vmin,Vtop,Vbase,
Vavg,Freq,Period,Risetime, Falltime, +Width,-Width,Overshoot,Preshoot,+Duty,-Duty,etc. - 10 Waveforms parameter Setups,Save,Reall.
- Vertical scale:2mV - 5V/div
- Sweep time:1ns - 50s/div
- Rise time:1.8ns - 14ns
- Power supply:100 - 240V,45 - 65Hz,<50W
- Dimensions:290(L)×330(W)×145(H)
Common Specifications:
Number of Channel: 2CH; Ext. Trig
Memory: 4K per channel
Vertical Sensitivity: 2mv/div-5v/div
Vertical Resolution: 8bits
Input Coupling: DC. AC. GND
Trigger Mode: Auto. Normal. Single
Trigger Type: Edge. TV. Pulse
Trigger Coupling: DC. AC. LF Rej. HF Rej
Horizontal Accuracy: ±0.01%
Math: + - × , FFT
FFT Window: Hanning. Hamming. Blackman. Rectangular
FFT Sample: 1024Points
Auto Measurement: Vpp. Vmax. Vmin. Vtop. Vbase. Vamp. Vrms. Vavg. Vover. Vpre
Freq. Period. Rise. Fall. +Width. -Width. +Duty. -Duty. DelayA. DelayB
Cursor Measure: Manual. Trace. Auto Measure
Storage: 10Wave forms.10 setups
I/O: USB device
Power: 100V-240V/50VA Max
Net Weight: 5kg
Size: 300(D) x312(W) x145(H)
Accessories: Probe x 2(1x.10x) Power Cord. User manual
Specifications:
Specifications
|
EM-OS-200B
|
EM-OS-150B
|
EM-OS-100B
|
EM-OS-60B
|
EM-OS-40B
|
|
Bandwidth
|
200MHz
|
150 MHz
|
100 MHz
|
60 MHz
|
40 MHz
|
|
Real time Sample Rate
|
1GS/S
|
|||||
Equivalent Sample Rate
|
50GS/S
|
|||||
Input Impedance
|
1MΩ//13pF 50Ω
|
|||||
Rise time
|
1.8ns
|
2.3 ns
|
3.5 ns
|
5.8 ns
|
8.8 ns
|
|
Time base Range
|
1ns/div-50s/div
|
2ns/div-50s/div
|
5ns/div-50s/div
|
|||
X-Y Operation
|
Bandwidth
|
200MHz
|
150 MHz
|
100 MHz
|
60 MHz
|
40 MHz
|
PhaseDHerence
|
±3degrees
|
|||||
Display
|
Color LCD(C)/Mono LCD(M)320x240
|
Specifications
|
EM-OS-150C
|
EM-OS-100C
|
EM-OS-60C
|
EM-OS-40C
|
EM-OS-25C
|
|
Bandwidth
|
150 MHz
|
100 MHz
|
60 MHz
|
40 MHz
|
25 MHz
|
|
Real time Sample Rate
|
500MS/S
|
|||||
Equivalent Sample Rate
|
50GS/S
|
|||||
Input Impedance
|
1MΩ//13pF 50Ω
|
|||||
Rise time
|
2.3 ns
|
3.5 ns
|
5.8 ns
|
8.8 ns
|
14ns
|
|
Time base Range
|
2ns/div-50s/div
|
5ns/div-50s/div
|
20ns/div-50ns
|
|||
X-Y Operation
|
Bandwidth
|
150 MHz
|
100 MHz
|
60 MHz
|
40 MHz
|
25 MHz
|
PhaseDHerence
|
±3degrees
|
|||||
Display
|
TFT/Color LCD(C)/Mono LCD(M)320x240
|
Common Specifications
|
||
Number of Channel
|
2CH;Ext.Trig
|
|
Memory
|
4K per channel
|
|
Vertical Sensitivity
|
2mv/div-5v/div
|
|
Vertical Resolution
|
8bits
|
|
Input Coupling
|
DC.AC.GND
|
|
Trigger Mode
|
Auto.Normal.Single
|
|
Trigger Type
|
Edge.TV.Pulse
|
|
Trigger Coupling
|
DC.AC.LF Rej.HF Rej
|
|
Horizontal Accuracy
|
±0.01%
|
|
Math
|
+ - × ,FFT
|
|
FFT
|
Window
|
Hanning.Hamming.Blackman.Rectangular
|
Sample
|
1024Points
|
|
Auto Measurement
|
Vpp.Vmax.Vmin.Vtop.Vbase.Vamp.Vrms.Vavg.Vover.Vpre
Freq.Period.Rise.Fall.+Width.-Width.+Duty.-Duty.DelayA.DelayB |
|
Cursor Measure
|
Manual. Trace. Auto Measure
|
|
Storage
|
10Wave forms.10 setups
|
|
I/O
|
USB device
|
|
Power
|
100V-240V/50VA Max
|
|
Net Weight
|
5kg
|
|
Size
|
300(D)x312(W)x145(H)
|
|
Accessories
|
Probe x 2(1x.10x)Power Cord. User manual
|