Atomic Absorption Spectrometer

Atomic Absorption Spectrometer

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
A&E LAB
Place of Origin:
China
Model Number:
AE-AA500FG

EvaWong

Business Type: Trading Company
Main Products:

Product Details

Features: 

Fully Automated

² The flame and graphite furnace is integrated into one instrument.The change over from one technique to another is carried out by simple key strokes within the software.

² The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and optimisation of each hollow cathode lamp by the software.

² The control of the gas flows for the fuel gas (C2H2 ) and the positioning of the bumer is also carried out directly from the software thus allowing optimization of the instruments for the best analytical parameter for a selected analysis.

² Two methods of background correction are available.The first utilises a deuterium lamp and the second is the proven method of self reversal.

² The location of the wavelength and peak selection is automatic and controlled from the software. The spectral bandwidth is automated and is available with a choice of five slit sizes.

² The electronic parameters for the photomultiplier detector,the hollow cathode lamp current and the balancing of the absorbance and background energies are controlled from the software.

² The igntion of the flame is computer controlled and the various safety interlocks offer a very safe operating system.

Technical Specifications

Model

AE-AA990

Modols:  AA990F: with Flame.

        AA990G: with Graphite Furnace.

     AA990FG: with Flame & Graphite Furnace 

Optic System

Wavelength Range

190nm-900nm

Monochromator 

Czemy-Turner Configuration

 Spectral Bandwidth 

0.1nm,0.2nm,0.4nm,1.0nm,2.0nm(5steps.

with automatic change over)

Wavelength Accuracy

   ±0.25nm

Wavelength Repeatability 

   0.15nm

Baseline Stability 

0.005A/30min

Flame analysis

Sensitivity(Cu):  0.03μg/ml/1%

Burner Head:    Titanium alloy burner

Atomization Chamber:  Corrosion-resistant material

Position Adjustment:   Automatic Changeover of Flame and Furnace

                    Automatic setting of Optimum Height for Flame Burner

Safety:  Automatic ignition and mixing air-acetylene gas with safety control.

Graphite furnace analysis

Character Value(Cd):  0.5Pg

Temperature Range:   Ambient-2650℃

Heating:  Voltage feedback control when dry and ashing; 

          Optical temperature control when atomizing.

Heating program:  Up to  9 steps with choices of ramp,temperature increase

                   and full-power heating

Background Correction: 

Deuterium Lamp Background Correction:  1.0Abs self-Reversal Background Correction: 3.0Abs

Date processing

Analytical method: flame,graphite furnace and hydride.