50kW CCD Detector Digital Radiography System YSDR01
Digital radiography system and China digital radiography system, provided by Guangzhou Yueshen Import & Export Co., Ltd
The unique Suspensory electrically controlled mechanical system, it can satisfied vertical position, lying position, sitting position and each kind of special helmet angle`s filming request, Extremely good counterweight balance design, reliable electromagnetism locks control device, operates cleverly, 100-180cm continuously adjustable SID in each kind of body position to obtain the perfect camera shot effect.Used in digital X-ray and a general health check-up, skull \ abdomen, back, pelvis extremities, a general health check-up, it is more convenient and nimble for electrical power steering.
Detector
X-ray detector uses KODAK VHD CCD by way of camera shot sensor, KODAK VHD CCD mainly uses in the outer space scientific research, has the superelevation sensitivity and extremely reliability, ultra long service life, This Digital Radiography System CCD detector compares with ordinary CCD detector has a higher sensitivity and more superior image quality, compares the flat detector has the longer service life and a higher reliability, higher spatial resolution and extremely low use-cost.
Detector performance parameters |
||
Item number |
1680A |
980A |
Imaging Ash |
65535rank |
65535rank |
Imaging Pixels |
16,800,000 |
9,800,000 |
Resolution |
4.6LP/mm |
3.6 LP/mm |
Image Bright |
≥12rank |
≥12rank |
Active Image Size |
14×17inch |
14×17inch |
Processed Image Display |
≤15s |
≤10s |
Bit Depth |
16bit |
16bit |
IMAGING DETECTOR SPECIFICATIONS |
||
Detector Array: Full field, single VHD CCD |
||
Active Image Size: 35cmx43cm (14”x17”) |
||
Pixels: 4,096x4,096 (16 Megapixel) 3,056 x 3,056 (16 Megapixel) |
||
Pixel Size (element pitch): 108 microns |
||
Spatial Frequency (Nyquist) : 4.6 lp/mm 3.4lp/mm |
||
Bit Depth: 16bit capture |
||
Fill Factor: 100% |
||
AEC:3 field |
||
Preview Image: Less than 6 seconds |
||
Processed Image Display Approximately 10 seconds |
||
Acquisition Cycle Time: Immediately upon display of previous image |
The high voltage generate equipment and X-ray tube |
uses the import generator which has 36-50kw isopotential high voltage, Its output electric power is extremely stable, guaranteed the image clear and trenchancy, it also has malfunction automatic detection software, built-in 99 kinds of exposures patterns, so the operation is convenience and the performance is stable. |
use the import high speed revolve bifocus X-ray tube, in the real-time the high voltage generator can examination the X-ray tube ‘s running status and achieves the best movement guarantees the image output the low noise. |
Allocation Table of Digital Radiography System |
||
Apellation |
specification and explanation |
QTY |
500mA high-frequency X-ray |
36-50kw high frequency generator |
1 |
Toshiba tube; |
||
360℃expansion U style of arm and flat bed; |
||
grid;ratio:1:8 ;180line/inch; 1.8m/1.0m; |
||
Manual Collimator; |
||
console:The programmable exposure technology contains 99 kind of procedures |
||
image detector |
1680A / 980A |
1 |
Vertical Stand Dedicated power |
12V Vertical Stand Dedicated |
1 |
USB Data transmission line |
12.8 meters high-speed USB Data transmission line |
1 |
Image acquisition workstation (lowest configuration) |
3.0G CPU, 17 inch high resolution LCD, 1G memory, 80G hard disk, 100M net card, DVD-R/RW |
1 |
Image acquisition software |
patient registration, image acquisition, cutting, negative image,image turning over, revolving, contraction and release, tagging, translation, demonstration, image window width and position adjustment, dicom image transmission, dicom film printing , worklist function, statistical inquiry image dedicated processing technology |
1 |
Image processing technology for special-purpose |
Dynamic range optimizationt echnology: |
1 |
automatically carries on the compression on |
||
the primitive image dynamic curve, achieving |
||
image characteristic that doctor is familiar with, |
||
being convenient to diagnosis |
||
High-frequency image enhancement technology: |
||
strengthen image contrast , enhance detail |
||
resolution,remarkably enhance high-frequency image |
||
quality of the bone trabecula, demonstrating more perfect. |
||
Noise abatement technology: |
||
automatically filtrate mixed frequency signal data , |
||
obviously reduces the image noise, Enhance image signal |
||
noise ratio, improved the image quality. |
||
Edge enhancement technology: |
||
automatically diagnostic and analytic image data, enhance image edge sharpness to make the image clearly |
||
Digital image workstation software |
DICOM receiving, transmission, inquiry, storage, film printing, report printing |
1 |
PACS/RIS and IBM server |
including the whole function of PACS/RIS |
1 |