Magnetic Latching Relay 120A
Negotiable /Piece
Min.Order:1 Piece
Haiyan Weijia Electric Technology Co., Ltd
Patent Number: 200820084302.1
Dimension: 52mm*52mm*25mm
Basic Data:
contact arrangement:1A.1B
contact material: sliver alloy
max switching current:100A.120A
max switching voltage:250VAC
max switching power:25KVA
Production Feature:
1.Wide gap between contacts, high switching capacity
2.Good insulation, High insulation resistance, as well as dielectric strength
3.Cassified as 100A and 120A
4.Resistive to shock and concussion, reliable to operate
Specification:
Coil Rated Voltage:9~48VDC
Coil Power: single:2.5W double:3.5W/2W
Set Voltage:≤80%
Reset Voltage:≤80%
Voltage Pulse Width:≥50ms
Set/Reset Time:≤30/30ms
Contact Bounce Time:≤5ms
Contact Resistance:≤2mΩ
Insulation Resistance:≥1000mΩ
Dielectric Strength Between Open Contacts:≥2000VAC
Dielectric Strength Between Open Contacts:≥4000VAC
Ambient Temp:-40~+70°c
Life Electrical (Operation): Normally 1*104 Particularly 3*104
Mechanical (Operation):1*105
Technical points.
1. Magnetic system: the patented technique is a smart and cleverish designed system which works with the structure of metal spiral-like magnetic shielding system without external electron magnetic interference. What's more, the fast push-pull effort of instaneous operation is fierce. Meanwhile, it owes trusted ability of resisting vibration and impact force as well as steady magnetic lock. The mechanical loss during its linear reciprocating operation is very little.
2. Contact operating system: it has very little mechanical loss due to its reform from inefficient swing-out lever operation to linear reciprocating operation. The use of the two-way flexible gap-free floating operation in its moving contact effectively reduces its contact bounce and extends the using life of contact. The big contact separating brake clearance effectively ensure the safely of the electrical properties; high contact close-brake pressure and lower voltage at rated load (<60mv) and lower temperature conductivity.
3. Magnetic latching relay pulse trigger parameters: the pulse amplitude and width rely on the accurate parts processing. The perfect manufacturing technique effectively ensures the long-term stability of the pulse trigger parameters of the magnetic latching relay.
4. Its mechanical-electrical integration system design and its internally installed circuits of commutations, boost pressure, stored energy and relay driving make the energy meter convenience, safe and reliable.