Product Details

Programmable 15KVA 20Kva 3 / 1 Phase High Frequency Online UPS with SNMP / USB / RS-232 port

Brand Name UPSEN
Place of Origin China
Model Number View Star Series 10-30Kva

Product Features

Delivery Time:7-15 Days
Certification:CE, ISO, RoHS

Programmable 15KVA 20Kva 3 / 1 Phase High Frequency Online UPS with SNMP / USB / RS-232 port    

Model:High Frequency Online UPS View Star Series 10K-30Kva (3ph in / 1ph out)

Quick Read

1: UPS with SNMP/USB/RS-232 communications port

2: UPS with adjustable battery numbers

3: UPS with long backup time

4: UPS with High Frequency Transformerless Tech

5: UPS with smart and compact design, high efficiency and low noisy

Key Features    

• True double-conversion on line UPS
• DSP technology guarantees high performance    
• Output power factor 0.8  
• Standard backup UPS and long backup UPS in one integrated unit
• Adjustable battery number from 16 pcs to 20 pcs
• Adjustable charging current via LCD or software
• Wide input voltage range (110-300 VAC)  
• Active input power factor correction 0.99
• 50Hz/60Hz frequency converter mode
• 3-stage extendable charging design for optimized battery performance
• Maintenance bypass available
• SNMP/USB/RS-232 communications
• Programmable power management outlets
• Emergency power off function (EPO) 
• Generator compatible 
• Charger capacity expansion to 12A for long-run models 
• Optional N+X parallel redundancy

Technical Specification

VIEW STAR SERIES ONLINE UPS SELECTION GUIDE
MODEL  VS31 10K (L)   VS31 15K (L)  VS31 20K (L) VS31 30K (L)
PHASE 3 phase in / 1 phase out
CAPACITY 10000 VA / 8000 W 15000 VA/12000 W 20000 VA/16000 W 30000VA/24000W
INPUT    
Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range  305-478 VAC (3-phase) @ 100% load
190-520 VAC (3-phase) @ 50% load 
Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧ 0.99  @ 100% load
OUTPUT
Output Voltage 208/220/230/240VAC
AC Voltage Regulation                   (Batt. Mode) ± 1%
Frequency Range                (Synchronized Range) 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (Max)
Harmonic Distortion  Less than 2 % THD (Linear Load)
 Less than 5 % THD (Non-linear Load
Transfer Time AC Mode to Batt. Mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY
AC Mode 89% 89% 89% 90%
Battery Mode 86% 88% 87% 89%
BATTERY
Standard Model Battery Type 12 V / 9 AH
Numbers 16 pcs 16 pcs x 2 strings 16 pcs x 3 strings
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A 2A 2A 2A
Charging Voltage  273 VDC ± 1%(based on 20 pcs batteries)
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers 16pcs(192V) 16pcs(192V) 16pcs(192V) 20pcs(240V)        (18-20adjustable)
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC ± 1%(based on 20 pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Batte

You May Like