retard AC voltage 250V Mine PE insulated underground Multicore Cable
Negotiable /Set
Min.Order:1 Set
New Baofeng Wire & Cable Co.,Ltd
waterproof 0.6 / 1kv with Silicone Rubber Insulate flexible Power cable for electric
Enterprise standard UGSP Rubber jacket Multicore Cable for movable transformer
high temperature resistant Insulated Heat resistant Power Multicore Cable -60 ~ 200
XLPE insulated PVC sheathed woven copper Multicore Cable for power transmission
Flexible Rubber Sheathed Multicore Cable with Rated Voltage 6Kv UGF-6000
GB1170-74, MT386 flexible rubber sheathed soft Multicore cables for mining purposes
retard AC voltage 250V Mine PE insulated underground Multicore Cable
Mine Sinal Cable
Product StandardEnterprise standard
UsageThis product is suitable for use retard AC voltage 250V and below coal mine underground with transmitting frequency below 30kHz.
Operating characteristics1, Allowed work temperature of cable for a long period should not exceed 70℃.
2, Temperature for laying cable should be not less than 0℃ and the min. bend radius is 10 time of cable overall diameter.
Type
Type |
Name |
Application |
PUYVP |
Mine PE insulated combustion retardant PVC sheathed signal cable |
ln underground electric field with relatively large disturbance |
PUYVR |
Mine PE insulated combustion retardant PVC sheathed soft signal cable |
As underground common signal or end instrument information transmitting line |
PUYVRP |
Mine PE insulated copper wire woven screened combustion retardant PVC sheathed soft signal cable |
ln underground electric field with relatively large disturbance |
For cable specifications
Type |
Nom cross-sectional mm2 |
Fabric of cores No./Diameter mm |
No. of cores |
PUYVP |
1.5 |
1/1.38 |
4 |
PUYVR |
0.5 , 1.5 |
7/0.30 , 7/0.52 |
4 |
PUYVRP |
0.75 |
7/0.37 |
2 , 3 |
Technical conditions
1. For structure size and chief technical parameters of this product
Type |
No. of cod×Nominal Area mm2 |
Insulation thickness mm |
Sheathed thickness mm |
Diameter mm |
Weight kg/km |
PUYVP |
4×1.5 |
0.7 |
1.6 |
14.0 |
265 |
PUYVR |
4×0.5 |
0.6 |
1.0 |
7.5 |
105 |
4×1.5 |
0.7 |
1.0 |
10.5 |
135 |
|
PUYVRP |
2×0.75 |
0.6 |
1.0 |
10.5 |
278 |
3×0.75 |
0.6 |
1.0 |
11.0 |
307 |
2. Conductor resistance (20°C)of cable should be not bigger than:
0.5 mm2 37.5Ω/km;
0.75 mm2 25.1Ω/km;
1.5 mm2 12.5Ω/km.
3. Cable should undergo AC 50HZ 1000V voltage test for 1 min, without being punctured.
4. Work capacity of cable should be not bigger than 0.061μF/km
5. Cable inductance should be not bigger than 0.716mH/km