vortex flowmeter
USD $530 - $530 /Piece
Min.Order:1 Piece
Meter Model | VT / VR4000 | VTC / VRC4000 | ||||
Connecting Forms | Piped | Plug-in | ||||
Accuracy | liquid | 1.0 ,0.75% | 2.0% | |||
Gases/ steam | 1.0% | 2.0% | ||||
Reproducibility | =+(-)0.2%( of rate ) | =0.2%( of rate ) | ||||
Allowable viscosity of measured medium |
=7.5mPs | = 7.5mPs | ||||
Typical flow Range | 1:20 | 1:8-1:30 | ||||
Sensor | Flange connection DIN | DN15-DN600 | ------- | |||
Wafer connection DIN | DN15-DN300 | ------- | ||||
Insertion type | ------ | Diameter of Pipeline > DN400 | ||||
Fluid Temperature | Standard | -55C--280C | -55C--280C | |||
High temperature | -55C--400C | -55C--400C | ||||
Pressure range | Standard | =100bar | =25bar | |||
Special | According to demands of users | According to demands of users | ||||
Material |
SS304,SS304L,SS316, SS316LAccording to demands of users |
SS304,SS304L,SS316, SS316LAccording to demands of users |
||||
Converter | Supply Power | 14-28V DC Battery-power | 14-28V DC Battery-power | |||
Cable Connection | M20x1.5,1/2 NPT | M20x1.5,1/2 NPT | ||||
Display | LCD display | LCD display | ||||
Communication |
HART-Protocol bus FF field bus |
HART-Protocol bus FF field bus |
||||
Ex-Design | Exia | Exia || CT6 | Exia ||CT6 | |||
Exd | Exd ||CT6 | Exd ||CT6 | ||||
Protection class | standard | IP67 | IP67 | |||
Diving
|
IP68 | IP68 | ||||
Ambient temperature | -40C-55C/-55C-70 C | -40C-55 C/-55 C-70 C | ||||
materials | Cast aluminum | Cast aluminum | ||||
Power consumption | 1W | 1W |