Local Glass fiber V Bank Filters HEPA H10 / H12 Filter With Big Air Volume
Negotiable /Metric Ton
Min.Order:1 Metric Ton
Glass Fiber H14 Compact HEPA Air Filter , Pharmacy Mini Pleat Hepa Filter
Stainless steel frame HEPA Air Filter For Laboratory / semiconductor
High Efficiency Blue Replacement HEPA Filters For Clean Rooms Class 100 - 10000
Anti - Static HEPA Filter Box , Replacement HEPA Filter Module
Semiconductor Clean Room HEPA Filter Box With Power Coated Flange
5 V-Bank HEPA Air Filter With Big Air Volume
Quicky Detail
Media: local glass fiber or HV glass fiber media
Frame: Aluminum or Galvanized Material
Gasket: PU Foam
Flange : 1 or 2 pcs
Flange size : 20x25mm
Pack: 4V or 5V
HEPA air filter efficiency: H10 - H14
HEPA air filter size: 610x610x292
Performance:
High purification rank, big media area , low resistance, big air volume.easy install and low operated cost .
Applications area:
5 v-bank HEPA air filter use for terminal filtration in air conditional system and big air volume clean equipment
Characteristics:
1: The v-bank HEPA air filter is the finally filtration in air conditional system that use for filter the particles more than 0.3um. Dedicated design the big air volume at low resistance.
2: High dust holding capacity: mini-pleats type , The filter media adopt the ultra-thin glass fiber , the hot-melt glue spacing each pleats in regular so that achieve high dust volume , the media area can be use in completely, this insure the high dust holding capacity .
3: High air volume: compare with other HEPA air filter, it loss more less media area at same air flow. This not only reduce the operate cost but also the time and space.
4: V-bank HEPA air filter with metal frame, we can make it with flange or without it for your choose.
5: Laser to scan the each air filter one by one.
6: The V-bank HEPA air filter efficiency range: H10, H11,H12, H13, H14
99.9%-99.9995%@0.3um (EN1822).
7: Each HEPA air filter with test report accompany.
Dimension and Parameter:
Dimension (W*H*D) (mm) |
pack |
Air flow (M3/h) |
Media area (m2) |
Holding dust(g) |
Primary resistance (by0.5m/s) |
Final resistance |
Efficiency (0.3um) |
287x287x292 |
2 |
700 |
4.45 |
330 |
<200 |
400pa- 600pa |
>99.99% H13-H14 |
592x592x292 |
3 |
2050 |
16 |
1000 |
<200 |
||
592x592x292 |
4 |
2700 |
21 |
1320 |
<200 |
||
592x490x292 |
4 |
2300 |
18 |
1100 |
<200 |
||
592x287x292 |
4 |
1350 |
10 |
650 |
<200 |
||
592x592x292 |
5 |
3450 |
27 |
1650 |
<200 |
||
592x490x292 |
5 |
2850 |
22 |
1370 |
<200 |
||
592x287x292 |
5 |
1700 |
14 |
1820 |
<200 |
||
610x610x292 |
5 |
3550 |
28 |
1700 |
<200 |
||
610x305x292 |
5 |
1800 |
14.4 |
870 |
<200 |
Customized size is available
Material and operation conditions:
Media |
Glass fiber media |
Sealant |
Hot melt glue , Polyurethane glue |
Frame |
Galvanized/Aluminum/SUS frame |
Gasket |
EVA, PU foam, Neoprene |
Pleat spacer |