0.3um Anodized Aluminum Frame Cleanroom HEPA Air Filter Both Side Screen
Negotiable /Set
Min.Order:1 Set
Galvanized Pharmaceutical HEPA Air Filter , Mini Pleat HEPA 10 / 12 Filter
Electrostatic Glass Fiber HEPA Air Filter Heat Resistant 99.999% 0.3um
H11 H13 Aluminum frame HEPA Air Filter For Clean Room Ceiling 99.999% 0.3um
DOP Terminal HEPA dust Filter Box / Cabinet For Clean Room 0.3-0.6m/s
DOP Terminal HEPA dust Filter Box / Cabinet For Clean Room 0.3-0.6m/s
0.3um Anodized Aluminum Frame Cleanroom HEPA Air Filter Both Side Screen For Decontamination Project
Quicky Detail
Media: Glass Fibre with foil clapboard
Frame: Anodized Aluminum or Galvanized Frame
Gasket: PU Foam or EVA Gasket
HEPA filter efficiency:99.99%- 99.999%@0.3um
H10 - H14
HEPA filter size: 305x610x150mm,
610x610x220mm.
1220x610x292mm
Resistance:<200pa
Performance:
Big media area, long time using life,Plenty of air volume , Low resistance, sufficiently dust holding capacity, the high efficiency, air flow regular.
Applications area:
HEPA air filter with aluminum separator widely use for electronic, pharmacy, food, semiconductor field , high purification rank machine, filtration system finally components.Part area Clean equipment and clean room.
Characteristics:
1: The HEPA air filter with aluminum separator is the finally filtration in clean room that use for filter the particles more than 0.3um.
2: The filter media adopt the ultra-thin glass fiber, the paper clapboard or the aluminum foil spacer in regular so that the refresh air pass through the media very easy. make the best of area used and increase the intensity of the pleats
3: The paper / aluminum foil media in 180 degree fold that compost of the wedge layer so that prevented the media damage.
4: The sealant around the media so that the air filter without any air leaking,
the frame can be MDF, AL or Galvanized material.
5: Laser to scan the each air filter one by one,
6: The HEPA air filter efficiency range: H10, H11, H12 H13, H14,
95%-99.99995%@0.3um (EN1822).
7: Each air filter with test report accompany
Dimension and parameter:
Dimension (W*H*D) (mm) |
Air flow (M3/h) |
Media area (m2) |
Holding dust(g) |
Primary resistance |
Final resistance |
Efficiency (0.3um) |
320x320x150 |
270 |
2.6 |
155 |
<200pa |
400- 600pa |
>99.99% H13-H14 |
484x484x150 |
600 |
6 |
360 |
<200pa |
||
610x610x150 |
1000 |
9.6 |
575 |
<200pa |
||
915x610x150 |
1500 |
14 |
900 |
<200pa |
||
1220x610x150 |
2000 |
19 |
1150 |
<200pa |
||
320x320x220 |
500 |
4 |
245 |
<200pa |
||
484x484x220 |
1000 |
9.5 |
600 |
<200pa |
||
610x610x220 |
1500 |
15 |
906 |
<200pa |
||
915x610x220 |
2300 |
22.6 |
1360 |
<200pa |
||
1220x610x220 |
3100 |
30.3 |
1800 |
<200pa |
||
320x320x292 |
600 |
5.7 |
350 |
<200pa |
||
484x484x292 |
1350 |
13 |
800 |
<200pa |
||
610x610x292 |
2200 |
21 |
1262 |
<200pa |
||
915x610x292 |
3300 |
31 |
1900 |