300m3/h DIN 24255 Single Stage Centrifugal Pump for Spray Booths
Negotiable /Unit
Min.Order:1 Unit
JETLC Domestic High Pressure Electric Water Pumps from Well , Swimming Pool
JETLB Self Priming Centrifugal Pump for Household / GardenSprinkling
Light Weight Small Submersible Water Pumps for Fountains / Ponds / Wells
DP-800SPH SS submersible Wastewater Pump For ChemicalIndustry
Industrial WQAS Sewage Water Pump , submersible dirty water pump
Mining / Architectural Sewage Water Pump dirty water submersible pump
300m3/h DIN 24255 Single Stage Centrifugal Pump for Spray Booths
MODEL EXAMPLE
TS 50 32-160
TS series centrifugal pump
50: Inlet size
32: Outlet size
16: Impeller dia.
0: Impeller series Number
According to standardized series DIN24255
Performance and working limits:
* Capacity up to 300m3/h
* Total head up to 91m
* Max. pressure 1 Mpa
* Max. temperature 140℃
* Min. temperature -20℃
DESCRIPTION
Monobloc single stage centrifugal pumps according to standardized series DIN24255
DESIGN ADVANTAGES
Reduced dimensions and weight installation without baseplate reduce cost
APPLICATIONS
TS pumps are suitable for industrial general services, refrigerated, heated and superheated water circulation in conditioning and heating systems; they are suitable for drinkable water, pressurization units, irrigation, extraction of condensate and low pressure boiler feeding. Suitable also for application in: spray booths, bottle washing plants, swimming pools, etc.
CONSTRUCTION
Single stage pump with radially split casing, axial suction and vertical discharge.
TS pumps are coupled to the motor by means of a casing cover/motor, cast in one piece.
Shielded, grease lubricated ball bearing do not need any Maintenance. Unbalanced standard mechanical seals(silicon carbide-carbon-vition).Flanges are according to UNI 2223
PN 16
MATERIAL:
Standard construction is: Casing and impeller in cast iron. Shaft in stainless steel AISI 240
Electric Motors:
Three phase induction Motor, Protection IP55, insulation class B.
Standard voltage is 220/380V,up to 3KW(4HP),380/660V from 4KW(5.5HP)upwards.
It is possible the use of motors with higher insulation class F and other voltage and frequency.