Galvanized steel wire strand/Guy wire / Stay wire 7/4.0
USD $600 - $1,150 /Metric Ton
Min.Order:1 Metric Ton
Henan Amity Industry Co., Ltd.
Galvanized steel wire strand/guy wire/stay wire
Application:
Galvanized steel wire and strand is used for ACSR,messenger wire,Guy wire,Stay wire,Earth wire,Damper,Helical Line Splices,Fence and so on.
Finish:Hot dipped
Content of Carbon:0.40%-0.85%
Galvanized steel wire:
Dia of wire:0.8mm-5.5mm
Galvanized steel wire strand:
Construction:1*3,1*7,1*19,1*37,
Dia. of wire in strand:1.2mm-4.25mm
1*19 Dia. of wire in strand:1.80mm-4.0mm
-
Standard:
ASTMA475,ASTMB498,BS183,BS4565,BS443,GB/T3428, YB/T5004,GB 1200-88,AS3607, AS1222, IEC60888,EN50189 and so on.
Tensile strength:900Mpa -1720Mpa
Zinc coating:120g/m2-549g/m2 Class A and Class B
Specifications for Galvanized steel wire
Diameter(mm) | Tensile strength(Mpa) | Weight of zinc(g/m2) |
1.24--2.25 | 1340--1620 | 185--215 |
2.25--3.00 | 1310--1590 | 230 |
3.00--3.50 | 1290--1550 | 245 |
3.50--4.25 | 1290--1520 | 260 |
4.25--4.75 | 1290--1520 | 275 |
4.75--5.50 | 1290--1520 | 290 |
Intensity level | Wire diameter (mm) | Min.tensile strength (Mpa) | Min.stress with 1% extension (Mpa) | Min.extension percentage when L=250(%) | Min.number of 360°twists | Diameter of testing mandril (multiple) |
General | >1.24--2.25 | 1340 | 1170 | 3 | 16 | 1 |
>2.25--2.75 | 1310 | 1140 | 3 | 16 | 1 | |
>2.75--3.00 | 1310 | 1140 | 3.5 | 16 | 1 | |
>3.00--3.50 | 1290 | 1100 | 3.5 | 14 | 1 | |
>3.50--4.25 | 1290 | 1100 | 4 | 12 | 1 | |
>4.25--4.75 | 1290 | 1100 | 4 | 12 | 1 | |
>4.75--5.50 | 1290 | 1100 | 4 | 12 | 1 | |
High | >1.24--2.25 | 1450 | 1310 | 2.5 | 16 | 3 |
>2.25--2.75 | 1410 | 1280 | 2.5 | 16 | 3 | |
>2.75--3.00 | 1410 | 1280 | 3 | 16 | 4 | |
>3.00--3.50 | 1410 | 1240 | 3 | 14 | 4 | |
>3.50--4.25 | 1380 | 1170 | 3 | 12 | 4 | |
>4.25--4.75 | 1380 | 1170 | 3 | 12 | 4 | |
>4.75--5.50 | 1380 | 1170 | 3 | 12 | 4 | |
Very high | >1.24--2.25 | 1620 | 1450 | 2 | 14 | 4 |
>2.25--2.75 | 1590 | 1410 | 2 | 14 | 4 | |
>2.75--3.00 | 1590 | 1410 | 2.5 | 12 | 5 | |
>3.00--3.50 | 1550 | 1380 | 2.5 | 12 | 5 | |
>3.50--4.25 | 1520 | 1340 | 2.5 | 10 | 5 | |
>4.25--4.75 | 1520 | 1340 | 2.5 | 10 | 5 | |
>4.75--5.50 | 1520 | 1270 | 2.5 | 10 | 5 |
Specifications for EN50189(zinc coated steel wires)
Zinc coating requirements | |||||||||||
Nominal wire Dia,mm | Class A | Class B | Class C | Class D | Class E | ||||||
Over | Up To and Incl. | Min mass of Zn. g/mm2 | Min.no of one minute dips | Min mass of Zn. g/mm2 | Min.no of one minute dips | Min mass of Zn. g/mm2 | Min.no of one minute dips | Min mass of Zn .g/mm2 | Min.no of one minute dips | Min mass of Zn. g/mm2 | Min.no of one minute dips |
1.24 | 1.5 | 185 | 2 | 370 | 3.5 | 150 | 1 | 365 | 3 | 185 | 2 |
1.5 | 1.75 | 200 | 2 | 400 | 3.5 | 160 | 1.5 | 460 | 3.5 | 200 | 2 |
1.75 | 2 | 215 | 2.5 | 430 | 4 | 175 | 2 | 550 | 4 | 215 | 2.5 |
2 | 2.25 | 215 | 2.5 | 430 | 4 | 190 | 2.5 | 550 | 4 | 250 | 3.5 |
2.25 | 2.75 | 230 | 3 | 460 | 4 | 190 | 2.5 | 640 | 5 | 250 | 3.5 |
2.75 | 3 | 230 | 3 | 460 | 4 | 205 | 3 | 640 | 5 | 250 | 3.5 |
3 | 3.5 | 245 | 3.5 | 490 | 4 | 260 | 3.5 | 730 | 6 | 250 | 3.5 |
3.5 | 4.25 | 260 | 3.5 | 520 | 4 | 275 | 4 | 730 | 6 | 260 | 3.5 |
GB 1200-88 Specifications for Zinc coated steel wire strand
No. of | Steel | Dia. | section area | Nominal tensile streng of Gal.steel wire (Mpa) | Approximate | ||||||||
1175 | 1270 | 1370 | 1470 | 1570 | |||||||||
Breaking strength of strand | |||||||||||||
| mm | mm | mm2 | kN≥ | kg/100M | ||||||||
1×7 | 1.60 | 4.8 | 14.07 | 16.53 | 17.87 | 19.28 | 20.68 | 22.09 | 11.17 | ||||
1.80 | 5.4 | 17.81 | 20.93 | 22.62 | 24.40 | 26.18 | 27.96 | 14.14 | |||||
2.00 | 6.0 | 21.99 | 25.84 | 27.93 | 30.13 | 32.32 | 34.52 | 17.46 | |||||
2.20 | 6.6 | 26.60 | 31.26 | 33.78 | 36.44 | 39.10 | 41.76 | 22.77 | |||||
2.30 | 6.9 | 29.08 | 34.17 | 36.93 | 39.84 | 42.75 | 45.66 | 23.09 | |||||
2.60 | 7.8 | 37.17 | 43.60 | 47.20 | 50.92 | 54.63 | 58.30 | 29.51 | |||||
2.90 | 8.7 | 46.24 | 54.33 | 58.72 | 63.36 | 67.97 | 72.60 | 36.71 | |||||
3.00 | 9.0 | 49.48 | 58.14 | 62.84 | 67.79 | 72.74 | 77.68 | 42.38 | |||||
3.20 | 9.6 | 56.30 | 66.15 | 71.50 | 77.13 | 82.76 | 88.39 | 44.70 | |||||
3.50 | 10.5 | 67.35 | 79.14 | 85.85 | 92.27 | 99.00 | 105.74 | 53.48 | |||||
3.80 | 11.4 | 79.39 | 93.28 | 100.82 | 108.76 | 116.70 | 124.64 | 63.04 | |||||
1×19 | 1.60 | 8.0 | 38.2 | 44.88 | 48.51 | 52.38 | 56.15 | 59.97 | 30.40 | ||||
1.80 | 9.0 | 48.35 | 56.81 | 61.40 | 66.24 | 71.07 | 75.91 | 38.49 | |||||
2.00 | 10.0 | 59.69 | 70.14 | 75.81 | 81.77 | 87.74 | 93.71 | 47.51 | |||||
2.20 | 11.6 | 72.22 | 84.86 | 91.71 | 98.94 | 106.16 | 113.39 | 56.69 | |||||
2.30 | 11.5 | 78.94 | 92.75 | 100.25 | 108.15 | 116.04 | 123.94 | 62.84 | |||||
2.60 | 13.0 | 100.88 | 118.53 | 125.12 | 138.20 | 148.29 | 158.38 | 80.30 | |||||
2.90 | 14.5 | 125.50 | 147.46 | 159.38 | 171.93 | 184.48 | 197.03 | 99.90 | |||||
3.00 | 15.0 | 134.30 | 157.80 | 170.56 | 183.99 | 197.42 | 210.85 | 105.43 | |||||
3.20 | 16.0 | 152.81 | 179.55 | 194.06 | 209.35 | 224.63 | 239.91 | 121.64 |
Specifications for Galvanized steel wire strand ASTM A475
(Concentrically stranded galvanized steel strand. Available in classes "A", "B" and "C" galvanizing, "A" being the least heavy and "C" being the most heavy. Available in five grades of strength: common, Siemens-Martin, high-strength, utilities, and extra-high-strength. Manufactured without welds per ASTM A-363 or with welds per ASTM A-475. Strands are formed to remain substantially in place when severed.)