Smart Capacitive 4-20mA Differential Pressure Transmitter (A+E-920B)
Smart Capacitive 4-20mA Differential Pressure Transmitter (A+E-920B)
Smart Capacitive 4-20mA Differential Pressure Transmitter (A+E-920B)

Smart Capacitive 4-20mA Differential Pressure Transmitter (A+E-920B)

Negotiable /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
AEAD
Place of Origin:
China
Model Number:
A+E-920B

Shanghai AEAD Technology Co. Ltd.

Business Type: Trading Company
Main Products: pressure transmitter , temperature transmitter , flow meter , flowmeter , level meter , pressure sensor , differential pressure transmitter , differenetial pressure sensor

Product Details

smart Capacitive 4-20mA Differential Pressure Transmitter (A920B)

A920B pressure / differential pressure transmitter is used to measure the density,
pressure and liquid level of the liquid, gas or steam, then converts them to 4~20mA DC
current signal output. A820C can communicate with HART manual operator to
complete setting and surveillance, etc.

Specifications
1. The reference accuracy for adjusting measuring range: (Including linearity,
    hysteresis and repeatability that begins from zero point, )
2. ± 0.2%If the measuring range is smaller than the upper limit of the measuring range,
3. ± [0.15+0.05 measuring range upper limit / measuring range]%

Ambient temperature impact:
    Total influence quantity/28 degree (50° F)

Diaphragm capsule Impact
            2 ± [0.08% measuring range +0.09% upper limit of measuring range]
            3 ± [0.07% measuring range+0.02% upper limit of measuring range]
            4 ± [0.07% measuring range+0.02% upper limit of measuring range]
            5 ± [0.07% measuring range+0.03% upper limit of measuring range]
            6 ± [0.07% measuring range+0.03% upper limit of measuring range]
            7 ± [0.07% measuring range+0.03% upper limit of measuring range]
            8 ± [0.07% measuring range+0.03% upper limit of measuring range]
             9 ± [0.07% measuring range+0.03% upper limit of measuring range]

4. Static Pressure Influence:
     A. Measuring range code 3: ± [0.1% measuring range+0.052% upper limit of
          Measuring range]/3.4MPa{500psi}
     B. Measuring range code 4, 5, 6: ± [0.1%measuring range+0.028%upper limit of
          Measuring range]/6.9MPa{1000psi}
5. Stability (M, H and V diaphragm capsule): ± 0.2% upper limit of measuring
    range/60 monthsZero
6. Adjustment: The zero point can be PV zeroed within the upper and lower limit
    of measuring range.
7. Installation position changes parallel to the membrane surface will not result in zero shift.
    If the installation position changes exceed 90° Against membrane surface, the zero shift
    within 0.4kPa can be adjusted through zero adjustment.
8. Output: 2-wire system, 4~20mA DC output, digital communication, it can be programmed
     to set linearity or square root.
9. Ambient Temperature:
      (-40~85) degree (-40~185° F)
      (-30~80) degree (-22~176° F) [with LCD header]
10. Liquid contact temperature: (-40~120) degree (-40~248° F)
11. Ambient Humidity: (5~100)%RH

Installation
1. Power supply and loading condition
2. The supply voltage is 24V and the maximum load is 570Ω .
3. Supply voltage:
     A. 10.5~42V DC (Working condition)
          (10.5~30V DC intrinsic safety type)
     B. 16.4~42V DC (digital communication and HART Protocol)
          (16.4~30V DC intrinsic safety type)Load:
4. 0~1335Ω (working condition)
5. 250~600Ω (digital communication)



Contact Supplier

Ms Fannie Cheng Chat Now
Telephone
86-21-51978797
Mobile
21-51978797
Fax
86-21-51978797
Skype
sense.cff
Address
273#, Debao Rd, China (Shanghai) Pilot Free Trade Zone Xi'an,Shaanxi

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Pressure Measuring Instruments > Pressure Transmitters
Categories