Wafer Flowtube Sensor Rosemount 8711 , compact lightweight flanged electro magnetic flowmeter
Negotiable /Meter
Min.Order:1 Meter
Beijing Zhongzhiguochuang Automation Equipment Co.,ltd
Flanged Flowtube Sensor for conductive liquids / slurries , Rosemount 8705
Rosemount 8750WA Electromagnetic Flowmeter System For Waste water Industry
high performance absolute pressure measurement Rosemount 2051TA
small compact Rosemount 2088A Pressure Transmitter for line pressure / tank level
industrial high performance Absolute Pressure Transmitter Rosemount 3051TA
Magnetostrictive liquid level transmitter for Oil Tank Level Measurement , 4 to 20 mA
Quick Detail:
· Manufactured by Rosemount
· Flangeless design
· Included alignment rings for easy installation
· 0.25% standard accuracy; 0.15% high accuracy option available
· 0.15 to 8 inch sizes available
· PTFE and PFA lining available
· 303 SST flowtube sensor
· Optional grounding electrode available
Description:
The Rosemount 8711 wafer flowtube sensor is designed for conductive liquids. The Rosemount 8711 is available in line sizes from 0.15 through 8 inches with a wide range of electrode materials to meet your needs.
The flangeless design of the Rosemount 8711 wafer flowtube sensor makes it an economical, compact and lightweight alternative to flanged magnetic flowmeters. Alignment rings provided with every Rosemount 8711, center the flowtube sensor in the process line for easy installation.
Rosemount magmeter systems use pulsed DC technology that provides continuous automatic zeroing to compensate for variations in the process environment. Process liquid must have a conductivity of 5 microsiemens/cm (5 micromhos/cm) or greater.
The Rosemount 8711 flowtube sensors are interchangeable with both the 8732E and 8712D transmitters. System accuracy on the Rosemount 8711 wafer flowtube is maintained regardless of line size or optional features. Each flowtube sensor nameplate has a sixteen-digit calibration number that can be entered into a transmitter through the Local Operator Interface (LOI) or the HART Communicator - depending on model.
Applications:
The Rosemount 8711 wafer flowtube sensor is designed for conductive liquids. The Rosemount 8711 is available in line sizes from 0.15 through 8 inches with a wide range of electrode materials to meet your needs.
Specifications:
Accuracy | Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown |
Line Sizes | 0.15-8 inch (4-200mm) |
Liner Materials | ETFE, PTFE, and PFA |
Electrode Materials | 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium Consult factory for additional material options |
Flange Ratings | ASME B16.5 Class 150-300 DIN PN 10-40 |
Interchangeability |
Compatible with all E-Series transmitters Compatible with Legacy transmitters · 8712D · 8712C · 8732C · 8742C |
Competitive Advantage:
The flangeless design of the 8711 wafer sensor make it an economical, compact, and lightweight alternative to flanged magnetic flowmeters. Alignment rings provided with every 8711 center the sensor in the process line and make installation easier.
· Lightweight, easy-to-install sensor for many common flow applications
· Wide range of sizes and electrode materials to meet your needs
· Cost-effective design
Flangeless construction for minimum size and weight Available in sizes from 0.15 to 8 inches (4 to 200 mm) ETFE-lined sensors comes with a choice of electrode materials to suit most process fluids PTFE-lined sensors are available for applications requiring FDA approved lining material