Normally Open Capillary Tube Thermostat

Main body temperature: T120 / T150
Faston Terminal Connections:6,3x0,8 mm DIN46244
Contact Closure Resistance:≤50mΩ
Insulation Resistance:≥100MΩ
.Min. electric current:200mA

Description:

Changsheng WQS-I series bulb & capillary thermostats are factory calibrated to a predetermined temperature range. This design offers a changeover thermal switch and an optional auxiliary switch that is useful for activation of an alarm or cooling fan. The principles of operation allow this design to be surprisingly cost effective and a leading choice for use in many applications where precision sensing is required while remaining on a tight budget. When temperature rises, the internal fluid located within the bulb expands through a capillary tube to an expandable diaphragm that is configured within the remote thermostat body. This diaphragm assembly activates the electrical contacts at the calibrated temperature set point. The WY-I series is available with a front auxiliary switch as optional.

Specifications:

  Normally close, open on temperature rise, manual reset, Earth Terminal Option

Working voltage and current

20 Amps @ 240 Vac

Ø Phial  diameter

3/6 mm

Cycles life

100,000 cycles

Open temperature

-35°C to 350°C  

Temperature Tolerance

±5°C, ±7°C, ±10°C, ±12°C

Differential Temperature

depending on open temperature

Contact resistance

≤100 m 

Capillary length

300~ 3000 mm; other lengths available upon request

Body temperature

T120 / T150 

Faston Terminal Connections

6,3x0,8 mm DIN46244

Contact Closure Resistance:

≤50mΩ

Insulation Resistance

≥100MΩ

Speed of response

1.0℃/min

.Min. electric current

200mA

Typical

  Model

Operating temperature

Switch

Voltage

(V)

Current

(A)

Maximum

Temperature

Sensing part(℃)

OFF(℃)

DIFF(K)

WQS70A-I

70±5

Manual reset

400/250

20

130

WQS95A-I

95±4

Manual reset

400/250

20

150

WQS140A-I

140±4

Manual reset

400/250

20

160

Applications:

■ -10 / +16 Refrigeration
■ -35 / +35 Fridge
■ 0 / 40 Ambient
■ 0 / 85 Boliers / Water heaters
■ 0 / 93 Dishwashers
■ 30 / 110 Bain Marie
■ 60 / 200 Deep-fryer
■ 50 / 250 Oven
■ 50 / 300 Oven
■ Other ranges upon request

Competitive Advantage:

1. VDE CE CQC Approved.

2. A variety of coating configuration and shell materials are available according to different usages

Contact Supplier

Miss. Wendy zhang sale Manager Chat Now
Telephone
86-519-85920008
Mobile
86-51985920008
Fax
86-519-85920222
Skype
wendyzhangjscs
Address
Xinhua Cun, Chunjiang Town, New-north District Zhoushan,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Chemical & Pharmaceutical Machinery > Chemical Machinery & Equipment > Heat Transfer Equipment
Categories
Hi~