KI67 Electric Motor Thermal Protection , Overheat Protection
Negotiable /Kilogram
Min.Order:1 Kilogram
Kain Electronic SCI&TECH. Company
250V 5A Light Weight Electrical Machine Overheat Protector For Air-conditioner
Customized Thermal Overheat Protection With Iron / Plastic Shell
KI67 Accurate Temperature Protector, Thermal Overheat Protection For Electric Equipment
Multi-function 250V 5A Overheat Protection , Thermal Protector For Electric Machine
Heat Resistance Motor Overheat Protection , Thermal Overload Protector
Thermal Overheat Protection / Micro Thermostats For Electric Machine
KI67 Electric Motor Thermal Protection , Overheat Protection
Motor overheat protector description Product description
KI67 universal and enhanced serial thermal protectors are widely used in industry , electrical household appliance and electric equipment to avoid abnormal operation caused by overcurrent and overtemperature . The products provide effective , reliable and safe protection . The enhanced casing is suitable for internal installation of plastic hermetic motor , which can bear the plastic molding pressure at 3.5Mpa . The performance of the products satisfies the standards including IEC34-11 , GB13232 , GB / T13002 , etc .
Structure and protection principle
KI67 type thermo protector is composed of the parts of thermal conductive casing , bimetallic parts welded with silver alloy contact point , conductive bracket , insulation fixation stand , fixed contact strip and heat resistance cable . When current passes through the bimetallic parts with resistance and in case of abnormal operation , along with the increase of current or the environment temperature rises to the set value , the bimetallic parts perform quick action , opens the contact point , and disconnects the circuit . When the device is cooled to the temperature for safe operation , the contact point will automatically closes and recover normal operation .
Design Detail
Note
1. Because the casing is made of conductive metal, thermal conductive and heat resistance insulation
sleeves are required for use.
2. Refer to A-C graph for selecting protection temperature.
Rated action temperature table
Type |
Open Temperature Range |
Type |
Open Temperature Range |
50℃ |
50±5.0℃ |
100℃ |
100±5.0℃ |
55℃ |
55±5.0℃ |
105℃ |
105±5.0℃ |
60℃ |
60±5.0℃ |
110℃ |
110±5.0℃ |
65℃ |
65±5.0℃ |
115℃ |
115±5.0℃ |
70℃ |
70±5.0℃ |
120℃ |
120±5.0℃ |
75℃ |
75±5.0℃ |
125℃ |
125±5.0℃ |
80℃ |
80±5.0℃ |
130℃ |
130±5.0℃ |
85℃ |
85±5.0℃ |
135℃ |
135±5.0℃ |
90℃ |
90±5.0℃ |
140℃ |
140±5.0℃ |
95℃ |
95±5.0℃ |
145℃ |
145±5.0℃ |
150℃ |
150±5.0℃ |
Note: The recovery temperature is 2/3 of the stan