Wireless Alarming Overload Energy Power Meter Calibrator With 7 Inch Touch Screen
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Artel Technology Co., Ltd,
Kwh Single-step Manually Power Monitoring Equipment Calibration For Harmonics
PC Measure Modular Relay Pulse Power Meter Calibration Monitor With Remote Control
Electric Utility Single Phase Power Meter Calibrator Instrument Export 2nd-21st Harmonics
200A Remote Communication Low - Voltage Overload M60 Protection Controller / Motor Protection Relay
Programmable Recording LCD 5A Motor Protection Relay, Controller With Automatic Inspection
7 Channels 250A 380VAC Flexible full - Ccale Motor Protection Relay, controller With Remote Communic
Wireless Alarming Overload Energy Power Meter Calibrator With 7 Inch Touch Screen
Product Profile:
AT6015C can calibrate single phase active & reactive energy meters
Main Features:
Accuracy : U, I, P, kwh: ±0.05%; Q, kvarh : ±0.1%; U, I, P stability : 0.01%RG/3min, AC Voltage and AC Current distortion : ≤0.2%; Current scope: Min. 0.05A, Max. 100A(Max output 120A); Voltage 100V-250V; Export 2nd-21st harmonics; Automatically or single-step manually test basic error, shunt running, start, standard deviation of single phase energy meter; Equipped with RS232 & Ethernet interface, AT6015C can be operated either stand-alone, or controlled by PC; Equipped with barcode gun interface, parameters of tested meters can be easily scanned in; Remotely updating online, easily achieve software updating; Self-protection, alarming and displaying overload location for Source-output overload, Voltage short-circuit, Current open-circuit; Self-diagnosis for amplifier failure and internal module communication failure; Test 3 energy meters with the same model type at one time; Test energy meters with the accuracy of Class 0.2 and below (Class 0.05 equipment);Technical Specification
Range |
Capacity |
Adjustment Degree |
Adjustment Range |
Stability |
Distortion (linear load) |
Measurement accuracy |
|
AC Voltage |
100~250V |
30VAmax |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
AC Current |
0.05A~100A |
100VAmax @100A |
0.01%RG |
0~120%RG |
0.01%RG 3min CL0.05 0.02%RG 3min CL0.1 |
0.2% CL0.05 0.5% CL0.1 |
±0.05%RG CL0.05 ±0.1%RG CL0.1 |
Phase |
0.00°~359.99° |
0.01° |
0.00°-359.99° |
0.01° |
±0.05° |
||
Frequency |
40Hz ~70Hz |
0.002Hz |
40Hz -70Hz |
0.002Hz |
±0.003Hz |
||
Power/Energy |
±0.05%RG CL0.05 ±0.1%RG CL0.1 pf≥0.5 |
||||||
Output Harmonics |
2nd to 21st |
0.01%RG |
≤40% |
Other Parameters
Aux. Power Supply |
AC 220V±15% |
Working Environment |