Magnetic Simple Low Voltage Active Buzzer 6V , Continuous Tone
Negotiable /Piece
Min.Order:1 Piece
CHANGZHOU FHD ELECTRONICS CO.,LTD.
5V PPO Black Active Electromagnetic Buzzer 12mm For Computer
Black Noryl Wireless Magnet Active Buzzer 5 Volt With Pins , D12mm*H9.5mm
Alarm Electromagnetic Transducer , Active Buzzer Rated Voltage Of 12V DC
Two Pin Active Buzzers , Magnet 12V Buzzer Element D16MM H14MM
Black Active Electro Magnetic Buzzer 5V With Cu Pin 80dB For Toy
Magnetic Simple Low Voltage Active Buzzer 6V , Continuous Tone
Quick Detail:
Size: D12mm*H6.5mm Rated Voltage: 5VDC Operating Voltage: 3-7VDC Rated Current: Max. 30mA at 5VDC SPL: Min.85dB at 10cm Input 5VDC Resonant Frequency: 2700300Hz ContinuousDescription:
buzzer Electro-Magnetic Transduer with build-in oscillating 5V Buzzer 12mm Electro-Magnetic BuzzerSpecification:
1.Technical Parameter
Measuring condition
Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.
1 |
Rated Voltage |
5 VDC |
2 |
Operating Voltage |
3 - 7 VDC |
3 |
Rated Current |
Max.30mA, at 5VDC |
4 |
Sound Output at 10cm |
Min.85dB, at 5VDC |
5 |
Resonant Frequency |
2700±300 Hz |
6 |
Tone |
Continuous |
7 |
Operating Temperature |
-20 - +70℃ |
8 |
Storage Temperature |
-30 - +80℃ |
9 |
RoHS |
Yes |
10 |
Weight |
Approx 1.5 g |
*Housing Material: Black Noryl
3. Reliability Test
After any following tests the part shall meet specifications without any degradation in
appearance and performance except SPL. SPL shall not deviate more than -10 dB
from the initial value
(1)Ordinary Temperature Life Test
The part shall be subjected to 96 hours at 25±10℃. Input rated voltage
Resonant frequency, 1/2 duty Square wave.
(2)High Temperature Test
The part shall be capable of with standing a storage temperature of +80℃ for 96 hours.
(3)Low Temperature Test
The part shall be capable of with standing a storage temperature of -30℃ for 96 hours.
(4)Humidity Test
Temperature:+40℃±3℃ Relative Humidity:90%~95% Duration: 48 hours
and expose to room temperature for 6 hours
(5)Temperature Shock Test
Temperature:70℃ /1hour→ 25℃/3hours→-30℃/1hour→ 25℃/3hours (1cycle)
Total cycle: 10 cycles
(6)Drop Test
Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,
three sides, six plain.)
(7)Vibration Test
Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes
Note:
As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it
4. Electrical And Acoustical Measuring Condition
Recommended Setting
Recommended Test Circuit
Packing