YHS-707 HART mode Process Loop Calibrator with Output 24V 0 -100% Span Check

YHS-707 HART mode Process Loop Calibrator with Output 24V 0 -100% Span Check

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
HAODI
Place of Origin:
China
Model Number:
YHS-707

Guangzhou Haodi Instruments Co.Ltd,

Credit Member 4 years
Business Type: Trading Company
Main Products: DMM Digital Multimeter ,Handheld Digital Multimeter ,Pocket Digital Multimeter

Product Details

Delivery Time:7-15days
Certification:ISO

YHS-707 HART mode Process Loop Calibrator with Output 24V 0 -100% Span Check

Quick Detail:

• 0 - 20 mA or 4 - 20 mA default start up modes. 

• Push button 25% steps for fast,  easy linearity checks. 

• 1 µA resolution for mA source,  simulate and measure. 

• 0-100% “span check” for fast confirmation of zero and span. 

• HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.

• 24 volt internal loop supply,  so you can power and read a transmitter at the same time without carrying a DMM.

Description:

This loop calibrator is designed with output current,  Simulate output current,  output voltage function,it is used for detecting and debugging automatic control equipment in industry scene.

Features 

• Measures V dc to 28 V. 

• 0 - 20 mA or 4 - 20 mA default start up modes. 

• Push button 25% steps for fast,  easy linearity checks. 

• 1 µA resolution for mA source,  simulate and measure. 

• 0-100% “span check” for fast confirmation of zero and span. 

• HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.

• 24 volt internal loop supply,  so you can power and read a transmitter at the same time without carrying a DMM. 

•Selectable slow ramp,  fast ramp,  and step ramp to provide smooth outputs for valve slewing and loop

• Innovative output adjustment dial with 1 µA and 100 resolution. 

• Single 9V battery that is easily changed without braking calibration seal 

• Simultaneous mA and % readout for quick,  easy interpretation of readings. 

• mA accuracy of 0.025%,  superior to other loop calibrators in this price range. 

• Large display and simple,  quick-click interface for easy one-handed operation functional tests.

Specifications

Current Measurement

Range:

0 to 24 mA

Resolution:

0.001 mA

Accuracy:

0.02% Rdg + 4 LSD

Current Sourcing

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.02% Rdg + 4 LSD

Drive Capability:

1200 Ω; 950 Ω at 20 mA in HART mode

Current Simulation

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.02% Rdg + 4 LSD

Ext. loop voltage requirement:

 12-30 V

Loop Power

 While measuring mA,  24 V

Voltage measurement

Range:

0 to 28 V DC

Resolution:

1 mV

Accuracy:

0.02% Rdg + 4 LSD

Contact Supplier

Mr. Li sale Manager Chat Now
Telephone
86-0755-54698745
Mobile
86-54698745
Fax
86-0755-54698745
Skype
alisa0518tape
Address
Dongming Building, Minkang Road, Minzhi Street Sanshai,Shandong

You May Like

New Products

Find Similar Products By Category

Automobiles & Motorcycles > Auto Electronics > Navigation & GPS
Categories
Hi~