Patient monitor-handheld patient monitor

Model:PM70

 

Feature

 

Routine Check Mode and

      Continuous Monitoring Mode

Data Graph and Trend Table Review

Rich Analysis Report

Sync with PC based Sofrware

     (WinXP and WinVista)

lightweight and easy-to-use portable unit

Built-in NIBP module

Automated & on-demand NIBP measurements

User or system-defined inflation pressure

ECG is optional

 

NIBP:

 

Performance Specifications

Display:3.5" Color TFT

Resolution:320x240

Display Mode:Standard face, Waveform face                

Indicator:Power indicator light, Alarm sound, Pluse tone

Interface:socket for connecting sensors and sockets

      for communication cables

Power Supply:DC 5V, <300mA

Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours

for continous working.8 hours for standby mode

Trend Graph:Resolution from 1s, 5s, 10s. Maximum time

      96 hours.

Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000

      items.

Alarm:Ajustable High and Low limits. Three level

     audible and vistual alarm

User Configuration:All the color of parameters and waves

      can be set according to user's willing

Technical specifications:

Safety

Meet the requirment of IEC60601 series

Type of Protection:Class II with internal electirc power

    supply

Degree of Protection:BF

Dimention and Weight

Dimention:145(W)x95(H)x37(D)mm

Weight:400g(with battery)

Operation Environment:

Temperature:0~ +40

Humidity:15% ~ 95%

Storage Environment:

Temperature:-20~ +60

Humidity:10% ~ 95%        

Patient Range

Neonate ,Pediatric and  Adult

 

SPO2:

 

Measurement Range:0 ~ 100%

Resolution:1%

Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)

                ±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified

Alarm Range:0% ~ 100%

Refreshing Rate:1s

Pulse Rate:

Measurement Range:25 ~ 250 bpm

Resolution:1bpm

Accuracy:±3 bpm (non-motion)

Alarm Range:25 ~ 250 bmp

Refreshing Rate:1s

 

NIBP:

 

Method:Oscillometry

Mode:Manual/Auto/Contiuous

Measurement Range:25 ~ 260mmHg

Atuo Measure Interval:5, 10, 15, 30, 45, 60, 90 ¡öminutes

Resolution:1mmHg

Overpressure Protection: 300mmHg

Alarm range: 25 ~260mmHg

Contact Supplier

Julia Commercial Manager Chat Now
Telephone
86-335-8015418
Mobile
86-15903392355
Fax
86-335-8015590
Skype
contec88
Address
No.24, Huanghe West Road, Economic and Technical Development Zone, Qinhuangdao City, Hebei Province, Qingdao,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Physical Therapy Equipments
Categories
Hi~