Finger Pulse Oximeter-CE&FDA
Negotiable /Kilogram
Min.Order:1 Kilogram
CONTEC Brand CE&FDA Approved Fingertip Pulse Oximeter Spo2 Monitor CMS 50D Finger Pulse Oximeter
Product name:CMS 50D Fingertip Oximeter
Manufacturer: Contec Medical Systems
Model: CMS 50D Fingertip Oximeter --CE&FDA Approved
The Fingertip PulseOximeter is registered on theAustralian Register of Therapeutic Goods (ARTG) with the code 136606,and certified by FDA of United States and CE,TUV of Europe.
CE & FDA Approved Fingertip Pulse Oximeter Spo2 Monitor CMS 50D Finger Pulse Oximeter
Fingertip Pulse Oximeter
Technical Parameters
1.Display Mode : Color OLED 6 Direction Display
2.SPO2 measuring range: 35-100%
3.Pulse Ratio:30-254 BPM
4.Pulse Waveform display: bargraph display
5.Battery indication: OLED display
6.Power Requirements: 1.5V(A A A size )Alkali Batteries×2
7.Adaptable range:2.6V-3.6V
8.Working current:≤25mA
9.Resolution: SPO2 : 1% Pulse Rate: 1bpm
10.Accuracy: SPO2 :70% to 100% ±2digits,below 70% unspecified Pulse rate:±2bpm or ± 2%(select larger)
11.Measurement at Low Perfusion: The values of SPO2 and pulse rate can be displayed properly when pulse saturation is at 0.4%.
12.Resistance to surrounding light: Deviation is smaller than ±1% between value of 13.Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.
14.Automatic shutdown function:The device will power off automatically within 5 seconds when there is no finger in the device. I.
15.When working,the display direction can be changed by pressing the button shortly.
16.There are six modes of direction. J.In working irem,long press can change the lighteness of the screen.
Content:
1. Pulse oximeter
2. Carry case
3. Landyard
4. Manual
Wattanty
All items are brand new, with 3 years warranty and whole life repair
About Us
We, Contec are professional medical equipment manufacturer for 17 years in China, we offer patient monitor, fetal doppler, fetal monitor, pulse oximeter, ECG, ECG Holter, EEG, EMG/EP, stethoscope.
Certifications from CONTEC Medical systems:
CE & ISO certification
FDA K Number
CMS50C Pulse Oximeter
Premarket Submission Number(510K): K073454
Listing Number: D045684
CMS50D/L/DL Pulse Oximeter
Premarket Submission Number(510K): K082641
Listing Number: D064765
Sonline A/B,Baby Sound A/B Pocket Fetal Doppler
Premarket Submission Number(510K): K082480
Listing Number: D072247
CMS50E,CMS50F,CMS60C,CMS60D Pulse Oximeter
Premarket Submission Number(510K): K090671 Listing Number:D078664,