Medical Diagnostic X-ray tube , Tungsten X-ray tubes for Dental X-ray unit
Negotiable /Piece
Min.Order:1 Piece
High Vacuum Diagnostic X-ray tube for Diagnostic X-ray machine , fluoroscopy machine 100KV
General Diagnostic X-ray tube for Mammography , AnodeX raytube for Medical 100kV
Two step X-ray Hand Switch with Omron micro switch for electric control parts
3 Cores PU X-ray Hand Switch for controlling on-off of electrical signal
2.2m 4 Wires X-ray hand switch for medical diagnostic X-ray photography exposure
Copper wires X-ray Hand Switch for X-ray photography exposure DC 30V
Medical Diagnostic X-ray tube , Tungsten X-ray tubes for Dental X-ray unit
Quick Detail:
Type:Station anode x-ray tube
Application: For intra-oral dental x-ray unit
Model: XD4-1.8/4.2-100
Integrated high quality glass tube
Description:
This tube, XD4-1.8/4.2-100 is designed for general medical diagnostic x-ray unit and available for nominal tube voltage with self-rectified circuit
XD4-1.8/4.2-100 tube has two focus.
The integrated high quality tube with glass design has one super imposed focal spot and a
reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for general diagnostic x-ray application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.
Applications:
This tube, XD4-1.8/4.2-100 is designed for general medical diagnostic x-ray unit and available for nominal tube voltage with self-rectified circuit
Specifications:
Nominal Voltage: ……………………………………………..……………………….100kV
Nominal Inverse Voltage……………………………………………………….….….110kV
Nominal Focal Spot…………………………………….……..1.8, 4.2(IEC60336/1993)
Filament Characteristics…………………………....…... …... ...small 4.5A, 5±0.5V
…………………………....…………………………….….. …..…. …large 4.5A, 10±1V
Target Material …………………………………………………………….……..Tungsten
Target Angle…………………………………………………………..….………………19°
Max. Anode Heat Content ………………..…………………….……….…………55000J
Continuous Rating…………….…………………….………………….….…………450W
Permanent Filtration ……………………………..Min. 0.6mmAl/50KV(IEC60522/1999)
Nominal Anode Input Power………………………………….……...…..small: 2500W
……….……………………………………..large: 10000W
Competitive Advantage:
Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime