Product Details

12V 3A Lead Acid Battery Charger With LED Indicator

Brand Name W&T
Place of Origin China
Model Number W&T-CH36W-A lead-acid

Product Features

Delivery Time:15-30 days
Certification:PSE UL CE GS EK FCC CB BS

 12V3A Lead acid battery charger,  with LED indicator, worldwide use 100-240VAC input
 
Quick Detail:
 

18-36W W&T Li-lon  battery charger, Input voltage: 100V-240V AC, 50/60HzRange voltage: 86V-265V AC, 47-63HzOutput power: 18~36WOutput voltage: Single output 4.5V 6V 9V 12V  15V 18V  24V 48VOutput voltage Ripple & Noise: Output voltage 2% MAXEfficiency: 65% MIXM.T.B.F: 50000HAC Inlet: IEC320-C14 , IEC320-C6, IEC320-C8

 
 
Competitive Advantage: 
 
 
High efficiency power(Level VI)
Meets \"ENERGY STAR\" program requirement
Over voltage protection
Over load & short circuit protection
100% full load burn-in test
 
 
Application:  
 
It’s suitable for an extremely wide range of applications, including:
 
• Li-lon/Ni-mh/Ni-hydrogen/Lead-acid battery
• printer
• MP3,MP4,MP5,
• Digital camera
• Electronics Toy
• Hard disk drive
• Audio & Video product
• Small Household appliance
E-Bike&Scooter charger
Electric tooling charger
Electric vehicle charger
Electric wheel chair charger
 
Specification datasheet :
 
 

INPUT

Voltage

90-264VAC universal full range

Frequency

47-63Hz

Current

<1.25A@100V AC input, full load condition

Inrush Current

<40A@115V , <60A@230V AC input.Cold start at 25℃ ambient

Leakage Current

<1.25A@ 264V AC input

OUTPUT

PART NO.

AD36WC4.5

AD36WC06

AD36WC09

AD36WC12

AD36WC15

AD36WC18

AD36WC24

AD36WC48

Voltage

4.5V

6V

9.0V

12.0V

15V

18V

24V

48V

Max Load

0-5.0A

0-5.0A

0-4.0A

0-3.0A

0-2.4A

0-2.0A

0-1.5A

0-0.63A

Output Tolerance

±5%

±5%

±5%

±5%

±5%

±5%

±5%

±5%

Ripple Noise(MAX)

50mV

50mV

90mV

120mV

160mV

200mV

240mV

400mV

Efficiency(MIN)

≥65%

≥65%

≥75%

≥75%

≥75%

≥75%

≥75%

≥75%

Output MAX

36W

36W

36W

36W

36W

36W

36W

36W

PROTECTION

Over Voltage

over 120%~150 max

Shutdown and latch off, recover after re-start up

Over Load &
Short Circuit

When power supply over 105%~150 max load or short circuit acted,powr supply will be shutdown and recover automatically after the fault is removed

Over Temperature

Over 95℃,the power supply will shutdown.

ENIRONMENT

Temperature

Operating:-20~70℃;De-rating:45~70℃:2.5%/℃;Storage:-40~+85℃

Humidity

Operating: 20%~90% RH(non condensing);Storage:10%~95% RH(non condensing)

SAFETY

Withstand voltage

I/P-O/P:3KVAC,I/P-PE:1.5KVAC,O/P-PE:0.5KVAC,1 minute

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG>100MΩ/500VDC at 25℃/70% RH

Safety standard

UL 60950-1 2nd,CSA C22.2 No.60950-1-07 2nd,TU EN 60950-1:2006,
IEC 60950-1:25005,standard, EN61558, EN60335, EN1310

EMC

EMI

EN 55022 CLASS B,FCC CFR 47 PART 15 CLASS B,CNS 13438 CLASS B

Compliance to EN61000-3-2 CLASS D,EN61000-3-3

EMS

EN55024:EN61000-4-2,3,4,5,6,8,11

OTHERS