Triangular microeave tower
USD $1200 - $1200 /Case
Min.Order:3 Cases
Qingdao Megatro Mechanical and Electrical Equipment Co., Ltd..
Triangular microwavetower is widely used and designed in microwave tower, broadcasting tower, TVtower, cell phone tower, and other application. And it is one trend to use more triangulartower instead four-legs telecom tower in most of African market and other countries.
Overten years MEGATRO has provided triangular microwave tower to toomany other Microwave Operator. MEGATRO design triangular microwave tower withgreat strength, low weight and wind resistance, and economy in the use ofmaterials. Our Lattices of triangular cross-section are most common in the microwavetower market.
After fabrication all Triangular microwave tower are delivered to thegalvanizing facility to be Hot DIP Galvanized. Towers are processed through thefacility by Caustic Cleaning, Pickling, and then Fluxing. These strictprocedures insure years of maintenance free towers. Sometimes, we also paintingthe towers as per clients requirements and other condition.
MEGATRO' Triangle mountain antenna tower systems can accommodate a variety ofdisc with network parts. MEGATRO also offers a wide variety of accessories andmounts.
Availability size: Based on the customer's requirements.
Material: MILD STEEL OR HIGH STRENGTH STEEL OR AS PER CLIENTS REQUIREMENTS
Package: Both parties discuss before delivery
Terms of Payment: L/C, T/T
Minimum Order Quantity: 5tons
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs
MEGATRO provide triangular microwave tower design with below requirements
Design Requirements and Basic of Design
MEGATRO TOWERS will guarantee the overall safety of the tower. MEGATRO TOWERSwill submit design calculation report for member design of tower and overallstructural stability of the structure, which is signed by a charted structuralEngineer.
MEGATRO will supply the skeleton to scale, showing the assembly of thestructures, the antenna mounting levels, other detail drawings etc.
The calculation method to be adopted for tower design will be decided byMEGATRO TOWERS with the consent of the client.
All materials will comply with British Standard (hereinafter called BS),Japanese Industrial Standard (hereinafter called JIS) or equivalent standards.The permissible stress of the materials will comply with BS, standard byArchitectural Institute of Japan (hereinafter call AIJ) or equivalent. Thestandards adopted for all materials will be stated separately.
General Design Criteria
Mast will be designed based on GB, BS 8100, TIA/EIA-222-G-2006, IS 802 &IS875 or equivalent international standards.
The wind loading on the tower and antennas mounted on it will withstand aground level wind velocity of 140 Km/h and survival speed of 180 Km/h includingwith height in accordance with latest BSI CP3: Chapter V: Part 2: BritishStandard (BS)
Antenna that will be considered when it calculates wind areas will be Six GSMantennas, Two each 600 mm diameter microwave dishes & one 1.2m Ø Microwaveplus all the feeders for GSM and MW antennas.
Allowance will be given to the effective windage area of the following:
Feeder runway
Feeders
Platforms and guard rails
Ladder and ladder guards
MEGATRO submit the complete data showing the drag factor from various angles ofwind on the antenna offered.