12x6.5MM Black Magnetic Electronic Buzzer Device Active , Noryl Housing
Negotiable /Piece
Min.Order:1 Piece
42MM 9 Volt Piezo Electric Buzzer Wire With Build-In Oscillating
90DB Passive Piezo Electric Buzzers , D44MMxH14MM Piezo Electric Buzzers
5V Self Drive Wire Piezo Electric Buzzers Continuous 3300Hz ISO9001
42x16MM Wire Piezo electric Buzzer 2.8KHz 1/2 Duty Square Wave
32x14.3MM Piezoelectric Buzzers , 90dB Sound 12 VDC Low Voltage
Active Piezo Electric Buzzer , Black PPO Piezo Transducer D30MMxH25MM
12x6.5MM Black Magnetic Electronic Buzzer Device Active , Noryl Housing
Quick Detail:
Size: D12mm*H6.5mm Rated Voltage: 5VDC Operating Voltage: 3-7VDC Rated Current: Max. 30mA at 5VDC SPL: Min.85dB at 10cm Input 5VDC Resonant Frequency: 2700300Hz ContinuousDescription:
buzzer Electro-Magnetic Transduer with build-in oscillating 5V Buzzer 12mm Electro-Magnetic BuzzerSpecification:
1.Technical Parameter
Measuring condition
Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure.
1 |
Rated Voltage |
5 VDC |
2 |
Operating Voltage |
3 - 7 VDC |
3 |
Rated Current |
Max.30mA, at 5VDC |
4 |
Sound Output at 10cm |
Min.85dB, at 5VDC |
5 |
Resonant Frequency |
2700±300 Hz |
6 |
Tone |
Continuous |
7 |
Operating Temperature |
-20 - +70℃ |
8 |
Storage Temperature |
-30 - +80℃ |
9 |
RoHS |
Yes |
10 |
Weight |
Approx 1.5 g |
*Housing Material: Black Noryl
3. Reliability Test
After any following tests the part shall meet specifications without any degradation in
appearance and performance except SPL. SPL shall not deviate more than -10 dB
from the initial value
(1)Ordinary Temperature Life Test
The part shall be subjected to 96 hours at 25±10℃. Input rated voltage
Resonant frequency, 1/2 duty Square wave.
(2)High Temperature Test
The part shall be capable of with standing a storage temperature of +80℃ for 96 hours.
(3)Low Temperature Test
The part shall be capable of with standing a storage temperature of -30℃ for 96 hours.
(4)Humidity Test
Temperature:+40℃±3℃ Relative Humidity:90%~95% Duration: 48 hours
and expose to room temperature for 6 hours
(5)Temperature Shock Test
Temperature:70℃ /1hour→ 25℃/3hours→-30℃/1hour→ 25℃/3hours (1cycle)
Total cycle: 10 cycles
(6)Drop Test
Standard Packaging From 75mm(Drop on hard wood or board of 5cm thick,
three sides, six plain.)
(7)Vibration Test
Vibration:1000cycles /min. Amplitude:1.5mm, Duration: 1 hour in each 3 axes
Note:
As this product is not protected from foreign material entering, please make sure that any foreign materials (e.g. magnetic powder, washing solvent, flux, corrosive gas) do not enter this product in your production processes. The functional degradation (e.g. SPL down) may occur if foreign material enter it
4. Electrical And Acoustical Measuring Condition
Recommended Setting
Recommended Test Circuit
Packing
Application:
CHANGZHOU FHD ELECTRONICS CO., LTD is a professional manufacturer in the field of micro acoustic products , our products is widely used in household electrical appliances; mobile phones;computers; medical equipment; alarm system; pos machine ;access control system; toy;automobile; instrument and meter;