DUK-2B Multi-Electrode Resistivity Survey System
USD $1 - $1 /Set
Min.Order:1 Set
China Dshing Import&Export Co.,ltd
· for high-resolution research, tomography and monitoring applications. landslides and other geological disaster exploration. Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters.
· High resolution engineering geological exploration like factory foundations, highways, bridges, railways, civil engineering, hydrology, engineering, environmental.
· Metal and non-metallic mineral resources exploration and geothermal exploration
· Main Features. Add storage and output functions for compensation SP voltage value.
· Assembly data acquisition devices and multiplexer together in the same case, reduce the volume and decrease the weight, avoid errors caused by operating the devices separately and due to inconformity of switch parameter settings.
· Maintain all functions of DUK-2A Multi-Electrodes Resistivity Survey System and conventional electrical method.
· Adopt 16-bit A/D and 16-bit D/A, thus improve the discernibility for measurement of collected data.
· Add the function for automatically detect grounding resistance before each measurement; give directions for the points exceed the grounding resistance value, for automatically proceeding with further measurement if required; the value at such point can be replaced with a fixed symbol to facilitate the elimination of this point while processing the information and data. Add high and low current transform taps, add high and low input impedance transformation tap, and improve the acquisition capability of weak signals.
· Greatly enhance the repeatability of measured data.
· Technical Specifications
Conversion Electrodes: 60 channels
· Power Supply: 1# cell, 8 pcs; or external 12V battery (cells to be taken out when Voltage Measuring Range: ±6V
· Current Measuring Range: 1μA~2000mA, 1μA~6000mA (two taps)
· Suppression on 50Hz Power Frequency: better than 80dB
· Measured Apparent Polarizability Accuracy: ±1%, ±1 digit
· Voltage Measuring Accuracy: 0.5%, ±1 digit
· Measuring Voltage Resolution: 1μV
· Measuring Current Resolution: 1μA
· Measuring Current Accuracy: 0.5%, ±1 digit
· Maximum Power Supply Voltage: 500VDC
· Maximum Power Supply Current: 2A
· SP Compensation Range: 1000mV
· Input Impedance: 20 MΩ, 100 MΩ (two taps)
· Storage Capacity: 1MB
· use the battery)
· Power Consumption: 250 mA (Standby)
· Working Temperature: -10℃~ +50℃, 95%Rh
· Weight: 8.5 kg
· Volume: 324×240×245mm