Fingertip pulse oximeter
USD $25 - $25 /Set
Min.Order:100 Sets
The Scope of Application:
PO-NW Fingertip Pulse Oximeter can monitor Pulse Oxygen Saturation, Pulse Rate, and Perfusion Index through patient’s finger. This device is applicable to hospital, home, community medical centre, alpine area and it also can be used before and after sports, and so on.
Features:
• Wireless data transmission can communicate with PC/mobile phone/PDA;
• External pediatric SPO2 probe available
• Large true color OLED display of SpO2, PR Pulse Bar, PI & Plethysmogram
• Automatic change display direction
• Automatic power on/off
• Audible & visible alarm function
• Pulse beep with pitch tone, pulse beep on/off and alarm limits can be set via setup menu.
• Shift parameter display between PR and PI
• 2AAA alkaline batteries with low power consumption
• Low battery voltage indication
Technical Specifications |
A. Display mode:Color OLED Display |
B. Power supply requirement: |
LR03 (AAA) alkaline battery × 2 |
Supply voltage: 3.0VDC |
Operating current: ≤40mA |
C. Environment requirement |
Operating Temperature: 5°C ~40°C |
Operating Humidity: 30%~80% |
Atmospheric pressure: 70kPa~106kPa |
D. SpO2 Parameter Specifications |
Transducer: Dual-wavelength LED sensor |
Measuring range: 35%~99% |
Accuracy: Not greater than 3% for SpO2 range from 70%-100% |
NOTE: Accuracy defined as root-mean-square value of deviation according to ISO 9919 |
SpO2 alarm: Lower limit: 90% |
E. Pulse Rate Parameter Specifications |
Measuring range: 30bpm~240bpm |
Accuracy: ±2bpm or ±2% (which ever is greater) |
Pulse Rate alarm: High limit: 120bpm |
Low limit: 50bpm |
F. Perfusion Index Display |
Range: 0%~20% |
G. The performance under low perfusion condition |
The accurancy of SpO2 and PR measurement still meet the precision |
described above when the modulation amplitude is as low as 0.6% |
G. Resistance to interference of surrounding light: |
The difference between the SpO2 value measured in the condition of |
indoor natural light and that of darkroom is less than ±1%. |
H. Resistance to 50Hz / 60Hz interference: |
SpO2 and Pulse Rate are precise which are tested by BIO-TEK pulse oximeter simulator. |
I. Dimensions: 66 mm (L) × 36 mm (W) × 33 mm (H) |
Net Weight: 60g (including batteries) |
J. Classification |
The type of protection against electric shock: |
Internally powered equipment |
The degree of protection against electric shock: |
Type BF applied part. |
The degree of protection against harmful ingress of liquids: |
Ordinary equipment without protection against ingress of water. |
Electro-Magnetic Compatibility: |
Group I, Class B |