Horizontal and Vertical Burning Tester: Key Specifications/Special Features:
Features:
Main reference of horizontal and vertical burning test are UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series of standards
It uses Bunsen burner with specified size and gas source (methane/propane)
According to certain flame height and angle to burning horizontal/vertical combustion test facilities several times to assess flammability and fire risk with fire, burning duration and length of burning
Horizontal and vertical burning tester is mainly for flammability l V-0, V-1, V-2, HB, 5V with grade material and for grading assessment
Specifications:
Burner:
Diameter: 9.5, ±0.3mm
Single gas and diameter: 9.5, ±0.3mm (single and mixed gas of Bunsen burner)
Test point: 0, 20 and 45° manual switch
Flame height: from 20, ±2mm to 180, ±10mm adjustable
Burning time: 0 to 999.9s, ±0.1s adjustable
After flame time: 0 to 999.9s, ±0.1s, automatically record, manual pause
After burning time: 0 to 999.9s, ±0.1s, automatically record, manual pause
Combustion gases: 98% of methane or propane gas (general LPG can be used to replace)
Flow pressure: meter and pressure gauge (gas and air)
Temperature test range: 0 to 1,000°C
Flame temperature requirements: from 100, ±5°C up to 700, ±3°C within 44, ±2s and 54, ±2s
Theromocouple (D): 0.5mm 2 import armor (type K) dual temperature system (50W) and 5VA/B (500W) grade
Test background: black
Test process: automatic control independent ventilation