High Current Mirco stepping 2 Phase Hybrid Stepper Stepper Motor Drivers CW8060
USD $20 - $35/ /Set
Min.Order:1 Set
Changzhou Smart Automation Motor Manufacturing Co.,Ltd
High Speed Micro - Stepping Two - Phase Hybrid Stepper Motor Drivers CW-1108
Bldc 60mm 4000RPM 36V Class B 4 Poles 3 Phase Bonded NdFe PM Brushless DC Motor
Bldc 42mm 8 Poles 3 phase Star 3500, 4000, 6300RPM Brushless DC Motor
57mm DC Delta Motors, Permanent Magnet Nema 23 bldc Brushless DC Motor
36V bldc 62mm 4 Poles 3 Phase Class B Bonded NdFe Brushless DC Motor
24V 4 Poles 3 Phase Bonded NdFeB Brushless DC Motor - Bldc 80mm
High Current Mirco stepping 2 Phase Hybrid Stepper Stepper Motor Drivers CW8060
Characteristics:
1.DC power input type:24V~80V
2.Output current:2~6A
3.Mircostepping:1(1.8º),1/2,1/4,1/8,1/16,1/32,1/64,1/128,1/256,1/5,1/10,1/25,1/50,1/125,1/250
4. Protect form : Overheated protect, lock automatic half current ,error connect protect
5. The maximum pulse rate is 200HZ.
6. Dimensions:147mm*97mm*30mm
7. Weight:<500g.
8. Working environment:Temperature-15~40℃Humidity<90%.
I/O Ports:
1.VCC+:DC power positive pole
Note:Must guard against exceeding 70V, so as not to damage the module
2.GND:DC power cathode
3.A+,A-:Stepping motor one winding
4.B+,B-:Stepping motor other winding
5.CP +,CP -:Stepping pulse input+5V (Rising edge effective ,rising edge duration >10μS)
6.CW +,CW-:Stepping motor direction input, voltage level touched off,high towards, low reverse
7.REST+,REST-: motor free
The interface see
NOTE:
1. When ambient temperature is high or working current over 3A, fix the module on big metal shell , or use axle flows fan dispels the heat, to make the module run reliably for a long time.
2. Half current automatically:if control machine not send out signal in half second, driver enter half current state of automatically for electricity saving, the phase current of the winding of the electric
3. The fault phase is protected : When the double-phase electrical machinery is connected with driver , users are apt to connect the phase by mistake, thus would damage the driver seriously. The protecting circuit is within this driver, when users connect by mistake, the driver will not be damaged, but the electrical machinery runs abnormally, shake , and output is small.Please check whether the wiring of electrical machinery is a mistake
Switch Choice: (“ON=0,OFF=1”)
1.Microstepping choice:
SW5 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
SW6 |
0 |
1 |
0 |
1 |
0 |
1 |
0 |
1 |
0 |
1 |
0 |
1 |
0 |
1 |
SW7 |
0 |
0 |
1 |
1 |
0 |
0 |
1 |
1 |
0 |
0 |
1 |
1 |
0 |
0 |
SW8 |
0 |
0 |
0 |
0 |
1 |
1 |
1 |
1 |
0 |
0 |
0 |
0 |
1 |
1 |
Micro |
1/2 |
1/4 |
1/8 |
1/16 |
1/32 |
1/64 |
1/128 |
1/256 |
1/5 |