UT-509, RS-485 Hub, Rail-mounted, Binding Post, Photoelectric Isolation, Serial Port Hub
Negotiable /Piece
Min.Order:1 Piece
UT-2204, 4-Port RS-485 / 422 Smart Server, W/Cache, Surging Protection, Serial Port Hub
UT-1208, Serial Port Hub, 8-port RS-232 / 485 / 422 Terminal Server, in Binding Post
UT-1304, Serial Port Hub, 4-port RS-485 / 422 terminal server, Photoelectric Isolation
UT-509, Serial Port Hub, RS-485 / 422 Repeater, Rail-mounted, Photoelectric Isolation
UT-754, 4-ports PCI to RS232 Multi PCI Serial Card with ESD protection, DR44 Female X 1
UT-754P, PCI Serial Card, 4-Port Industrial RS-232 PCI Multi-Serial Port Card, DCD, RXD
UT-509, RS-485 Hub, Rail-mounted, Binding Post, Photoelectric Isolation, Serial Port Hub
Applications:
RS-485 is widely used in thruway toll system, road supervision system and electric power acquisition system as a high-performance and economical data interface converter.
Electric interface and its definition:
RS-232C interface definition
10-bit wiring terminal |
Definition |
Signal description |
1 |
GND |
Ground |
2 |
GND |
Ground |
3 |
GND |
Ground |
4 |
485- |
RS-485 Negative signal input |
5 |
485+ |
RS-485 Positive signal input |
6 |
GND |
Ground |
7 |
RXD |
RS-232 Signal receive |
8 |
TXD |
RS-232 Signal transmit |
9 |
VCC |
Power input DC40V |
10 |
GND |
Power Ground |
RS-485 interface definition
10-bit wiring terminal |
Definition |
Signal description |
1 |
T/R1+ |
RS-485 signal output + |
2 |
T/R1- |
RS-485 signal output - |
3 |
T/R2+ |
RS-485 signal output + |
4 |
T/R2- |
RS-485 signal output - |
5 |
T/R3+ |
RS-485 signal output + |
6 |
T/R3- |
RS-485 signal output - |
7 |
T/R4+ |
RS-485 signal output + |
8 |
T/R4- |
RS-485 signal output - |
9 |
GND |
Isolation ground |
10 |
GND |
Isolation ground |
Description:
UT-5204 is a RS-485 bus-division hub designed for RS-485 system used in complicated electromagnetic environments. It supports data communication rate up to 115.2KBPS. Photoelectric isolation technique is introduced to the RS-485 interface to prevent converter and device from lightning and surge voltage for ensuring the safe and reliable data communication. The built-in photoelectric isolator (an isolation voltage as high as 2.5KVrms) and 600W surge suppressor can effectively suppress lightning and ESD and the grounding interference with each RS-485 line. It uses external switching power supply for safety and reliability and is ideal for outdoor engineering applications. The built-in discrimination circuit can automatically sense the direction of data flow and switch the enable control circuit to ensure the automatic switch of transmit and receive in RS-485 mode.
Short-circuit and open-circuit protection are provided for each port. Users can improve the RS-485 bus structure and divide bus segments conveniently for improved com