Power Cord Strain and Twist Tester
Negotiable /Piece
Min.Order:1 Piece
Guangzhou Zhilitong Electromechanical Co., Ltd.
Power Cord Strain and Twist Tester
Product details:Model ZLT-LN1. Appliances provided with a supply cord, and appliances intended to be permanently connected to fixed wiring by a flexible cord, shall have a cord anchorage. The cord anchorage shall relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
A mark is made on the cord while it is subjected to the pull force shown in follow table, at a distance of approximately 20 mm from the cord anchorage or other suitable point.
The cord is then pulled, without jerking, for 1 s in the most unfavourable direction with the force specified. The test is carried out 25 times.
The cord, unless on an automatic cord reel, is then subjected to a torque that is applied as close as possible to the appliance. The torque is specified in following table and is applied for 1 min.
Table – Pull force and torque
Mass of appliance Kg |
Pull force N |
Torque Nm |
≤1 |
30 |
0,1 |
>1 and ≤4 |
60 |
0,25 |
>4 |
100 |
0,35 |
During the tests, the cord shall not be damaged and shall show no appreciable strain at the terminals. The pull force is reapplied and the cord shall not be longitudinally displaced by more than 2 mm.
Power Supply |
220V 50Hz or 115V 60Hz |
Pull weight |
10N*1,60N*1 and 20N*2 |
Torque weight |
2N*1,5N*1,7N*1(0.1Nm,0.25Nm,0.35Nm) |
Tension times |
0~9999(selectable) |
Tension frequency |
1 times/s |
Torque time |
0.1S~999S(selectable) |
Conforms To |
IEC60335-1 clause 25.15 |