Volt/mA Calibrator YHS-715
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd
YHS715 Volt/mA Calibrator is a source and measurementtool. This Calibrator can be used in measurement or output 0 to 24 mA DCcurrent loop, and0 to 10 V DCvoltage.
Measure loop current (0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution Measure voltage output process signals from PLCs, transmitters Source or simulate24 mA loop current Source voltage to 100 mV or 10V 24V loop supply with simultaneous current measurement Enhanced voltage and current measure and source accuracy Improved battery life 250 ohm HART resistor with loop power Holster features test lead storage Compatible with toolpack magnetic hanging system Step and linear ramp output function Configurable zero and span settings Functional specifications
Measure / Source mV |
Range: |
0 to 100 mV |
Resolution: |
0.01 mV |
|
Accuracy: |
0.02% + 2 counts |
|
Measure / Source V |
Range: |
0 to 10 V |
Resolution: |
0.001 V |
|
Accuracy: |
0.02% + 2 counts |
|
Measure / Source/ Simulate mA (% of span) |
Range: |
0 to 24 mA (-25% to 125%) |
Resolution: |
0.001 mA |
|
Accuracy: |
0.015% + 4 counts |
|
Note: Sink (simulate transmitter) Display mA or % of span |
LoopPower |
Range: |
24 V dc |
Accuracy: |
10% |
|
Note: Drive; 20 mA into 1000 Ω for battery >6.8V; 700 Ω for battery 5.8 to 6.8 V |
||
Display |
Clear 5 digit LCD |
Weight: |
350g(include battery) |
Size: |
190mm× 89mm × 42mm |
Battery: |
9VDC, 006P or 1604 |