Max 5T Insulation Resistance Measurement YH 510
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd
1.Measurement of Insulation Resistance for HP Devices (Transformer, Electric Cable, and Electric Machines, etc)
2.Built-in High Power Voltage Generator (250V ~ 5kV Adjustable)
3.Auto Computation and Display of PI (Polarization Index) and DAR (Dielectric Absorption Rate)
4.Stepped Voltage Test, Temperature Compensation, Temperature Measurement, and Leak Current Measurement
5.Data Storage and Upload Function
Features
Test Voltage and Insulation Resistance Measurement in Broad RangeTest voltage ranges from 250V to 5kV, in 25V stepped setup, and able for measurement of 5TΩ insulation resistance in maximum.
Supports Various Insulation Judgments
Data Storage and Upload Function
Able to manually store 100 data, automatically record 10 groups of data (360 measurement points in maximum for each data group), and automatically record date and time.
Carrying Case
Hard carrying case adaptable to field application is adopted.
Chargeable batteries can be used at the same time
Able to be loaded with 2# batteries and chargeable batteries at the same time, and when capacity of one group of batteries is insufficient, it can be switched to another group for further use.
Temperature Measurement |
10~70°C±1.5°C |
Display |
LCD Display, with Back Light |
Hot Line Voltage AC, DC Frequency |
50~750V ±50~±1000V 50Hz/60Hz |
Display Refresh Rate: |
1 Time/s(0.25 T/s during use of average value function) |
Output Voltage Monitoring: |
2 Times/s |
Voltage Measurement: |
4 Times/s |
Temperature Measurement: |
1 Time/s |
Analog Bar: |
2 Times/s |
MAIN FUNCTIONS
Measurement of Insulation Resistance and Leak Current
Test Voltage: DC250V~5.00kV, Test Insulation Resistance 0 –5TΩ; Max Test Current 1mA
Able to display insulation resistance, leak current, PI, DAR, and measurement time.
Stepped Voltage Test
Test voltage is gradually increased to measure variations of insulation resistances and leak currents under different voltages.
Two types of stepped voltage values are optional, and measurement time can be selected for respective stepped stages.
Display of PI (Polarization Index) and DAR (Dielectric Absorption Rate)
Able to automatically measure parameters of PI and DAR.
Measurement of
Precision of Measurement: ±5%rdg.±5%dgt
Data Storage Function
Able to manually store 100 groups of data, and also able to automatically record 10 groups of data, with each group able to store 360 measurement points in maximum.
Data Uploading Function
Able to upload the store data into PC through USB interface, to be formed into graphic charts and to be printed for filing, and also able to set up and modify measurement parameters at PC end.
Supports USB2.0 (Full Speed)
Parameter Indicators
Environmental Range of Temperature and Humidity: 0~40°C, 90%rh below (non-condensed)
Battery: 6# Battery x 6 | Ni-MH Chargeable Battery, 7.2V
Max Rated Power: 15W
Time for Continuous Use: Dry batter can last 5 hours and chargeable battery can last 9 hours, under the condition of 5kV generation, ports disconnected and back light closed.
Max Rated Voltage to Ground: 600Vrms(CAT IV),1000Vrms(CAT III)
Insulation Level: AC7000V 15s between electrical loop and casing.