VLF Series 0.02Hz 80kV Very Low Frequency Tester
USD $1 - $1 /Bag
Min.Order:1 Bag
GDHL Series 100A, 200A, 400A, 600A Contact Resistance Tester, Micro ohm meter
GDTF-HTS Series AC Resonant Test System for Substation Equipment
GDGK-307 Fully Automatic Circuit Breaker Mechanical Characteristics Tester
GGDGK-306 High Voltage Circuit Breaker Tester, HV Switch Tes
GGDGK-306 High Voltage Circuit Breaker Tester, HV Switch Tes
Introduction:
1. The VLF Series 0.02Hz 80kV Very Low Frequency Tester is suitable for Testing cables, transformers, switchgear, Rotating machinery, and other Electrical apparatus.
Features:
1. Easiest to use Fully automatic micr℃ontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients
14. Short circuit protected.
15. Status display of all important safety functions and messages.
16. Safe, easy to use operation with emergency off and key switch l℃k-out.
17. Fully integrated discharge circuit to safely ground the DUT after testing.
18. Zero start interl℃k.
19. Zero voltage switching.
Specification:
1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage. 30KV
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation <0.5%
5. Measurement accuracy: ± 3%.
6. Positive and negative voltage peak errors: ≤ 3%.
7. Voltage waveform distortion: ≤ 5%
8. Construction: In two units: Controller and Booster.
9. Ambient conditions of use: Temperature Indoor and outdoor: -10ºC to + 50ºC.
10. Humidity: ≤ 85%
VLF Models for Option :
Output | Load Capacity | Controller | Booster | ||
Model | Voltage/Current | Frequency/Capacitance | Size | Dim.(cm) | Fuse Tube |
VLF-30/1.1 | 30KV/20mA | 0.1Hz ≤ 1.1uF | 28*37*22cm, 4kg | 33*18*34,25kg | 5A |
0.05Hz ≤ 2.2uF | |||||
0.02Hz ≤ 5.5uF | |||||
VLF-40/1.1 | 40KV/30mA | 0.1Hz ≤ 1.1uF | 28*37*22cm,4kg | 35*20*36,35kg | 6A |
0.05Hz ≤ 2.2uF | |||||
0.02Hz ≤ 5.5uF | |||||
VLF-50/1.1 | 50KV/40mA | 0.1Hz ≤ 1.1uF | 28*37*22cm,4kg | 37*24*39,45kg | 7A |
0.05Hz ≤ 2.2uF | |||||
0.02Hz ≤ 5.5uF | |||||
VLF-60/1.1 | 60KV/50mA | 0.1Hz ≤ 1.1uF | 28*37*22cm,4kg | (33*18*34cm, 25kg)*2 | 10A |
0.05Hz ≤ 2.2uF | |||||
0.02Hz ≤ 5.5uF | |||||
VLF-70/0.5 | 70KV/55mA | 0.1 Hz, ≤ 0.5µ F | 28*37*22cm,4kg | 33*18*34cm, 25kg;35*20*36cm, 35kg | 10A |
0.05Hz, ≤ 1.0µ F | |||||
0.02Hz, ≤ 2.5µ F | |||||
VLF-80/0.5 | 80KV/60mA | 0.1 Hz, ≤ 0.5µ F | 28*37*22cm,4kg | 33*18*34cm, 25kg 37*24*39cm, 45kg | 12A |
0.05Hz, ≤ 1.0µ F | |||||
0.02Hz, ≤ 2.5µ F |