FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

Negotiable /Set

Min.Order:100 Sets

Supply Ability:
1000 Set / Sets per Month
Port:
GUANGZHOU
Payment Terms:
T/T Credit Card

Quick Details View All >

Type:
Medical Centrifuge
Brand Name:
TOPMEDI
Place of Origin:
Guangdong, China
Model Number:
TCMS50D

Guangzhou Topmedi Healthcare Co., Ltd.

Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: electric wheelchair ,manual wheelchair ,leisure wheelchair ,sport wheelchair ,hospital bed

Product Details

Specifications

1, Photoelectric Oxyhemoglobin Inspection Technology
2,uitable for being used in family, hospital, oxygen bar, community health

Major Features

Principle of the TCMS50D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology

 is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be 

used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being 

used in family, hospital, oxygen bar, community healthcare, physical care in sports 

(It can be used before or after doing sports, and it is not recommended to use the device during the process

 of having sport) and etc. 

FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

 

 

Major Features

Integrated with SpO2 probe and processing display module

 Small in volume,light in weight and convenient in carrying

Operation of the product is simple ,low power consumption

SpO2 value display

Pulse rate value display, bar graph display

Pulse waveform display

 The display mode can be changed

 Screen brightness can be changed

 Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage

 Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe.

 Display format can be saved after power off

 

Main performance

Display Mode:0.96" Dual-color OLED display(blue and yellow)

Screen Resolution:128*64

SpO2 Measuring Range:0%~100%, (the resolution is 1%).

 Accuracy:70%~100%:±2% ,Below 70% unspecified.

PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)

 Accuracy:±2bpm or ±2% (select larger)

Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).

Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%

Power Consumption:less than 30mA

Voltage: DC 2.6V~3.6V

Power Supply:1.5V (AAA size) alkaline batteries × 2   

Battery working hour: Theoretical number is 32 hours.

Safety Type:Interior Battery,BF Type

 

Accessories

Sell in standard

a hanging rope

a user manual 

 

Physical Identity

Dimension:57(L) × 31(W) × 32(H) mm

Weight:About 50g (with the batteries)

 

FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 MonitorFDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 MonitorFDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 MonitorFDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 MonitorFDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

FDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 MonitorFDA&CE finger pulse oximeter TCMS50D plus FW with Spo2 Monitor

Contact Supplier

Mr. Ares Chan Account Manager Chat Now
Telephone
86-020-22105997
Address
RM1505-1507, Golden Sky Tower, No. 83, Middle Huadi Road, Liwan Dist., Guangzhou, 510380, China Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > General Assay & Diagnostic Apparatus
Categories
Hi~