ROC-2015 single stage reverse osmosis controller
1 General The controller is of an automatic operation management controller designed for small-scale first-class anti-osmosis water preparation system, which can realize automatic operation of anti- osmosis devices only by adding few electric elements at periphery. It has digital input (DI) ports in five states and four output control ports, and it is a small-scale economical controller. 2 Main Technical Specifications Supply voltage | AC220V+10% 50/60Hz | Power consumption | <2W | Environmental conditions | 1) Temperature: 0-50C | 2)Humidity: <85%RH | Load capacity of output contacts | 5A/250V AC (resistive load) | Dimensions | 48*96*80mm (height*width*depth) | Hole size | 44*92mm (height*width) |
|
ROC-2015 RO Controller Main functions Dry-run protection function | It is used to monitor water source when raw water is cut off (low level of water storage tank and the pressure of pipeline getting too low) to prevent from system idling. The controller stops the operation of whole RO system, while the indicator light on panel for “LOW FEED PRESS” lightens and buzzer sounds. After that, the controller will detect dry-run switch uninterruptedly, and if the water supply pressure or water level returns to normal, the controller will restart RO system for operation. | Low-pressure protection function | When front-end pretreatment system is in flushing or regenerating state, the security filter being dirtied and jammed, and cannot supply normal feeding pressure for RO system (namely the low pressure is insufficient) , the controller will temporally shut down the whole RO system. At this moment, the indicator light for “LOW PRESS” and the buzzer sounds. Then, the controller will continuously detect the low-pressure protection switch, and after the pressure recovery for 1 minute, RO control system will start at first time, and operate RO system. In event of low-pressure protection for system again, stop the operation of RO system. The procedure sets three times of trial running, and when they are not successful, the system will enter deadlock protection state. The indicator light for low-pressure protection is on to reminder the reason to shut down, and is waiting for restart by pressing the reset key after treatment by manpower. | High-pressure protection function | In some systems with high-pressure protection, if the system has overpressure, the controller will automatically close the whole RO system, and the indicator light for "HIGH PRESS" lights up. After elimination of high pressure for 1 minute, the controller will perform trial running at the first time. If the outlet pressure still has overpressure, the system will become into protection state again. The high-pressure protection procedure sets three times of trial running, and when they are not successful, the system will go into deadlock protection state and the buzzer sounds. *If the system has no high-pressure protection, short out the terminal (COM+HP) | Pure water tank level Control function | When pure water tank level is at preset low level, the controller will start RO system immediately to generate water till the level of pure water tank up to the preset high level, and the system will flush membranecompletely and shift to standby state. | Membrane flushing function | When the protective device and state is normal, the system will perform membrane flushing every time power up, and then repeat it every low-level water preparing. When the water producing tank is filled, the membrane flushing will be automatically ended. |
|