ACO-001 air pumps for aquariums
Negotiable /Set
Min.Order:1 Set
Shenzhen Reliable Electromechanical Technology Co., Ltd.
< ACO-001 air pumps for aquariums >
This series of pumps is non-Lubrication one,which gives off Very clean air,
it can be used for aquatic breeding,restaurant and live aquatic product keeping,
also can be used for food packing,spraying,electronic circuit board welding,
Supporting medical equipment,environment equipment,the use of gas stoves,etc..
OUTLOOKDIMENSONS:
FunctionCurves:
REATURES:
1.Convent to operate without oil,noise and air pollution
2.Cylinders and pistons ae of excellent materials, which is strong and duerable and have little wear long time of working
duct specific,wide adaptation.
4.The structure is compact and innovative modeling,using high-quality materials,advanced manufacturing,small size,light weight.
5 Smooth operation.
6 Energy,gas volume,the ratio of the electromagnetic pump air compressor power is about one-fifth of the traditional structure,a significant energy-saving,low-voltage suitable for only exhaust pressure,the amount of gas occasions.
7.The use of power (voltage and frequency) allow Fluctuations+/-10%,with the power indicated on air pump Nameplate (labels)not too high or too low are normal and extreme damage to the pump.
8.Wording environmental temperature should within degree and maintain good
Ventilation and smooth to prevent excessive temperature .
9.Air pump should de prevented from rain drenched and soaked water.
Not in the heat of the sun or the dust environment.Before use it,make sure the earth
line is well equipped .Do not touch the power with wet hands
if it falls into water,cut off the power first and then take it out from water.
You must use it after after.the skilled worker make sure it is safe for you to use it
if you find electricity leak,please cut off the power at once.
You should use after it is repaired.
10.Pump must be installed flatly 20 centimeters above the water level and kept
immovable in order to prevent liquid from flowing back and the pump breaking.
11.Pump could not bear oil.water and collision
12.You should clear the filter sponges at least once every one month
13.The general acreage of the tube should not be less than 855% of acreage of pump
out let.
14.Try to equip the tube Bend less than 120 degrees,to avoid excessive presses losses,
Affectreslts.
15.Cut off the power if you don’t use it tor a long time and put it on the Ventilated place.please operate it about ten minutes every one month in order to make sure it is not broken and could run smoothly when you need
if the capability is reducing,please check:
1) Whether Voltage is beyond the certain rang.
2) Whether air filter,tube,the joint is broken or stocked
3) Whether pump valve,diaphragm is broken or stocked
4) if located in the bad aircirculated place,it will lead to the higher temperature,
tue lower,please improve the heat diffusing
When fault can not be ruled out ,please bring in distribution point,or linked our company.