TC60NB-6T PV Array Combiner Box/6 in 1out combiner box/AC distribution box
USD $200 - $400 /Set
Min.Order:1 Set
Yunnan Yaochuang Energy Development Co., Ltd.
TC40NB-4T PV Array Combiner Box/4 in 1out combiner box/AC distribution box
30A to 150A MPPT Solar Charge Controller for Off-grid solar system
10A 20A 25A 50A 100A MPPT PWM Solar Charge Controller 60V 72V 96V 110V 120V
36V 48V MPPT/ PWM Solar Charge Controller 30A 40A 50A 60A 80A 100A
10A 20A 30A 40A 50A 100A PWM MPPT Solar Charge Controller with manual
TC40NB-4T
PV Array Combiner Box
1,IDENTIFICATION AND DESCRIPTION
1.1,In order to better use product, please read the following instructions symbol.
WARNING! This symbol identification for informal operation might be in the safety of users dangerous or may cause significant hardware damage. | |
INDICATE! This symbol identification for good system required for the operation of the matters needing attention. |
1.2,Installation before use, please read this manual.
WARNING! All the operation and line connection ask professional personage to operation. | |
WARNING! Please pay attention to personal and equipment safety. | |
WARNING! Please note that photovoltaic array input of positive and negative polarity and the total output of the positive and negative polarity. | |
WARNING! Installation or connection PV modules, please note PV modules produce high voltage, avoid shock hazard. | |
WARNING! Ensure that the connection of fastening, for the user to use improper or cable wiring the loss caused by unstable, the company does not undertake any responsibility. |
2,PRODUCT INTRODUCTION
Photovoltaic power generation system, in order to reduce the photovoltaic module and inverter between the connecting cables, convenient maintenance, reduce the loss and improve the safety and reliability of the product, generally require in the photovoltaic module and inverter added between confluence device.
Photovoltaic junction box besides having the function of PV bus outside, and at the same time, should also have a current counter-attack, over current protection, over-voltage protection, lightning protection and a series of perfect protection function.
This company produces the photovoltaic junction box with the above various functional requirements, and photovoltaic (PV) grid, from network type inverter supporting the use can form a complete set of photovoltaic power generation system solutions.
Select photovoltaic junction box, the user can according to the back end inverter input voltage range, output power size, a certain number of specifications of the same PV module series, parallel composition PV module series coordinate access photovoltaic junction box (see Figure1) bus, and then after circuit breaker control and lightning protection device protection after output for level inverter use.
Main features:
l The most can access 6 road PV array, single road input array maximum current for 10A;
l Output may withstand the maximum current for 60A the highest open circuit voltage for 880VDC;
l Single way photovoltaic array to join high voltage fuse protection, counter-attack protection ;
l Photovoltaic special high pressure lightning protection device protection;
l Photovoltaic special high voltage circuit breaker control output;
l Meet outdoor installation requirements, protection class IP65;
l RS485 remote monitoring function (optional).
3,STRUCTURE
3.1,Components list
Numbers | Function declaration |
1 | Photovoltaic array input is (fuse) |
2 | Photovoltaic array input negative |
3 | DC circuit breaker |
4 | Photovoltaic array input counter-attack |
5 | output plus and minus |
6 | SPD |
7 | Ground |
3.2,Model shows
Figure 2 Model shows
4,TECHNICAL DATA
Model | TC60NB-6T |
Input data | |
PV array input numbers | 8 |
MAX single PV array current | 10A |
Single PV array fuse | 10A |
Single PV array wire size | PG9,4mm2 |
Output data | |
Output numbers | 1 |
MAX output current | 60A |
MAX output voltage | 880VDC |
DC output circuit breaker | yes |
Output wire size | PG21,16mm2 |
Others data | |
Protection | IP65 |
Temperature range | -30℃ ~ +60℃ |
Reference weight | 14Kg |
Size(D X W X H) | 400mm X 300mm X 160mm |
Cooling way | Natural cooling |
SPD protection | yes |
Ground wire size | ≥6mm2 |
5,INSTALLATION AND USE
5.1,Device check
The customer received the goods please check the packing list, if any discrepancy please immediately contact with the company!
1,PV array combiner box; 2,key;
3,certificate ; 4,Warranty card;
5,User manual; 6,Product inspection report;
5.2,Installation size
Please arrange professionals and strictly in accordance with the above dimensions for operation.
5.3,Fast connection
In order to improve the connection of rapidity and convenience, the chassis allow flip door, with key can be easily open and shut case for line connection. Photovoltaic input connections and output connecting line in case two side, users in the connection when please ensure that all the connecting line and equipment are reliable connection.
5.4,Over-current protection
When the PV module input current is too large, the fuse will break for protection; In addition, miniature circuit breaker also can prevent the system from current is too large, have over-current protection function.
WARNING! It is strictly prohibited to work in touch fuse, inspection or replacement is required before the fuse will dc circuit breaker off; Must be replaced with the original model of the same magnitude fuse. |
5.5,Over-voltage protection
When the PV module input voltage is high, the miniature circuit breaker will automatically disconnect, have overvoltage protection function.
6,APPENDIX
6.1,Quality assurance
This product quality assurance period 1 year, otherwise stipulated in the contract period of the contract shall prevail.
6.2,Evidence
Products in the quality assurance period require customers to buy the products show the invoice and date. At the same time the product of the trademark shall be clearly visible, or shall have the right to not be quality assurance.
The following situation, this company has the right to not to quality assurance:
1,Man-made damage to the equipment;
2,Wrong installation and use;
3,When using the maximum limit parameters beyond equipment requirements;
4,Abnormal natural environment damage caused;
5,Beyond that in this manual are very bad environment operation;
6,Beyond the relevant international standards specified in the installation and use of range.
6.3,Contact us
Do you have any questions about our product welcome to contact jackie wang and i will gladly for you to answer!