120--500M3/H Air To Air all heat exchanger recovery for plate ventilation for air recuperator
USD $350 - $800 /Set
Min.Order:1 Set
Xiamen AIR-ERV Technology Co., Ltd.
90--380M3/H Air To Air all heat exchanger for plate ventilation supplying for air recuperator
800--1000 M3/H Air To Air all heat exchanger for recovery plate ventilation for air recuperator
500--600M3/H Air To Air all heating energy for recovery plate ventilation for air recuperator
300--400 M3/H Air To Air all heating energy for air recuperator
Energy Recovery Ventilator
Item No:K-04DE
Specification
Model type: Heat & Humidity
Airflow: Cross flow
Power type:DC
Maximun Static pressure: 290Pa
Adjust: By pass
Air volume: 120--500m3/h
Noise: 25dB(A)
Exchanger core material: fiber paper
Function: Outdoor & indoor air exchanger
Place: Home/office/meeting room/factory room/ farm
Surface stick: Silencers cotton
Size:745x800x268 (mm)
Power:7--155 (w)
Rated voltage:220V
Temperature efficiency:60%--73%
Enthalpy efficiency:55%--70%
Weight:38kg
Features
Product description:
KRV series stand for energy recovery ventilator, the heat exchanger core is cross flow paper core, the major function is remove the exhaust air(stable indoor air) and replace it with fresh outdoor air, improve the air quality. It is suitable for installation in Home, office, meeting room. Not only exchanger fresh air, but also save energy.
Features:
1.Indoor and outdoor two-ways ventilation, equivalent exchanger of fresh air;
2.Low noise, corrosion and high tempreture resistant;
3.Paper core:high moisture-permeating rate, good air-tightness, tearing-resistance and aging-resistance
4.High heat recovery efficiency;
5.Sealed process stucture,easy to contral and maintain
Main parameter:
Model | Air Volume (m3/h) | Static Pressure (Pa) | Rated Voltage | Input Power (W) | Summer | Winter | Noise | Dimension (mm) | Re. weight (kg) | ||||||||||
TemperatureEfficiency (%) | Enthalpy Efficiency (%) | Temperature Efficiency (%) | Enthalpy Efficiency (%) | ||||||||||||||||
High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | ||||
K-02DT | 200 | 150 | 75 | 65 | 220V/50Hz | 80 | 58 | 75 | 77 | 58 | 62 | 75 | 77 | 69 | 72 | 30 | 27 | 665×580×268 | 26 |
K-03 DT | 300 | 250 | 85 | 75 | 220V/50Hz | 107 | 78 | 76 | 77 | 56 | 60 | 76 | 77 | 67 | 70 | 32 | 29 | 745×600×268 | 32 |
K-04 DT | 400 | 350 | 90 | 80 | 220V/50Hz | 142 | 121 | 76 | 77 | 54 | 58 | 76 | 77 | 66 | 68 | 34 | 30 | 745×800×268 | 38 |
KRV energy recovery ventilator Work principle:
Ceil Installation, save space:
WELcome to visit Energy recovery ventilator