roof ventilation fan with heat recovery for workshop
Negotiable /Piece
Min.Order:1 Piece
Xiamen AIR-ERV Technology Co., Ltd.
Name: roof ventilation fan with heat recovery for workshop
- Airflow various from 150-3500m3/h
- Sensible and latent heat recovery
- Quiet operation
- Suspended installation
- Bypass-function
- Optional standard controller and intelligent controller
odel | Air Volume (m3/h) | Static Pressure (Pa) | Rated Voltage | Input Power (W) | Summer | Winter | Noise [dB(A)] | Dimension(mm) | Re. weight (kg) | ||||||||||
Temperature Efficiency (%) | Enthalpy Efficiency (%) | Temperature Efficiency (%) | Enthalpy Efficiency (%) | ||||||||||||||||
High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | ||||
K-02DT | 200 | 100 | 75 | 80 | 220V/50Hz-60Hz | 65 | 70 | 76 | 75 | 59 | 58 | 76 | 75 | 69 | 69 | 30 | 28 | 665×580×268 | 26 |
K-03DT | 300 | 250 | 85 | 75 | 220V/50Hz-60Hz | 107 | 78 | 76 | 77 | 56 | 60 | 76 | 77 | 67 | 70 | 30 | 25 | 745×600×268 | 32 |
K-04DT | 400 | 350 | 90 | 80 | 220V/50Hz-60Hz | 142 | 121 | 76 | 77 | 54 | 58 | 76 | 77 | 66 | 68 | 32 | 26 | 745×800×268 | 38 |
K-06DT | 600 | 500 | 100 | 90 | 220V/50Hz-60Hz | 190 | 162 | 70 | 72 | 50 | 53 | 70 | 72 | 61 | 64 | 33 | 31 | 820*900*268 | 48 |
K-08DT | 800 | 700 | 120 | 100 | 220V/50Hz-60Hz | 320 | 302 | 73 | 75 | 50 | 55 | 73 | 75 | 64 | 69 | 34 | 30 | 1110×880×388 | 73 |
K-10DT | 1000 | 900 | 100 | 80 | 220V/50Hz-60Hz | 410 | 360 | 74 | 77 | 54 | 58 | 74 | 77 | 66 | 70 | 36 | 32 | 1110×1135×388 | 92 |
K-16DT | 1600 | 1400 | 150 | 130 | 220V/50Hz | 815 | 750 | 75 | 77 | 57 | 59 | 75 | 77 | 65 | 68 | 42 | 38 | 1350*1220*437 | 95 |
K-20DT | 2000 | 1800 | 200 | 170 | 220V/50Hz | 980 | 945 | 76 | 78 | 59 | 61 | 76 | 78 | 66 | 68 | 44 | 40 | 1450*1220*500 | 110 |
K-22DT | 2200 | 1600 | 100 | 210 | 1580 | 1260 | 74 | 77 | 56 | 59 | 74 | 77 | 62 | 67 | 56 | 50 | 1500X1330X500 | 133 | |
K-16D | 1600 | 150 | 380V/50Hz | 650 | 75 | 57 | 75 | 65 | 43 | 1350*1220*437 | 98 | ||||||||
K-20D | 2000 | 150 | 380V/50Hz | 1013 | 76 | 59 | 76 | 68 | 45 | 1450*1220*500 | 125 | ||||||||
K-25D | 2500 | 110 | 380V/50Hz | 1875 | 72 | 54 | 72 | 65 | 50 | 1550×1330×548 | 146 | ||||||||
K-30D | 3000 | 60 | 380V/50Hz | 1525 | 75 | 58 | 75 | 68 | 55 | 1550*1330*548 | 165 | ||||||||
K-35D | 3500 | 100 | 380V/50Hz | 2245 | 76 | 58 | 76 | 68 | 55 | 1630*1600*548 | 210 |
Model | Ventilation core | Function | Heat |
KRV | Be made of antiseptic,antimicrobial fibrous Paper and ABS Framework | Recovery heat energy | Total Heat |
The working principle of a heat recovery ventilation unit is to exchange energy in the air in a two-way exchange system by using heat differences of the inside and outside temperatures. It has several functions; as well as heat recovery it functions as a heat-conductor.
The output of the extractor unit utilises energy from the intake air via an effective heat exchanger
to contribute to reducing the buildings energy requirement. Energy-saving rates of up to 75% can
be achieved with a KRV heat recovery system.
Features:
1> Different capacity units provide easy and flexible solutions for rooms of all sizes
2> Consistent performance over long periods of operation
3> A side air flow design largely increases the life expectancy of the heat exchanger
4> Easy maintenance - only the filter needs maintenance.
5> Low noise. Fire foam Fan volute, completely sound-absorbing, less noise, higher heat efficiency.
6> 3 speed air volume control, high, medium, low 3 speed to adjust the air volume.
7> New high-dormant-pressure with two-way air inlet centrifugal turbine. The units are now equiped with new and improved fan
blades giving the heat recovery unit has a larger deflection diameter. As a result, when air flows, the dormant pressure is increased
and the noise is reduced. High dormant pressure and low noise are reliable and perfect for air conditioning designs.
8> High quality special fibrous paper core,with high moisture permeability,good air-tightness,anti-rends,
aging resistance,anti-mildew.
We care about all the details in the product process.
As roof ventilation fan with heat recovery for workshop has the soft character to cause the easy deformation, we focus on the safe packing in different transportation way.
Full container | PVC bag + strong carton (pallet for option) |
LCL | PVC bag + special strong carton + pallet |
By air / courier | PVC bag + carboard inserted in carton + special strong carton |
Introduce of AIR-ERV
AIR-ERV in China is the professional manufacturer of Total energy exchanger manufacturersand heat products.
Founded in 1996,we have 20 years of experience.
Introduce of AIR-ERV
1. AIR-ERV can supply OEM service for customers.
2. Produce ERV/HRV, heat exchanger according to customer's special demands.
3. Supply spare parts according to order quantity.
4. General testing and operational test carried out for every units before delivery.
5. Long warranty period.
Welcome to visit our roof ventilation fan with heat recovery for workshop