Cross-counter flow heat recovery ventilator core
USD $1 - $1,000 /Piece
Min.Order:100 Pieces
Xiamen AIR-ERV Technology Co., Ltd.
We supply cross-counter flow heat recovery ventilator core.
1. products name :cross-counter flow heat recovery ventilator core
2. cross-counterflow
3. anticorrosion hydrophilic coating aluminum foil
4. pitch: 2.5-10mm
5.galvanized sheet
************************************************************************************************************
If you are insteresting in cross-counter flow heat recovery ventilator core,click here to contact with Jenny Yang.
************************************************************************************************************
Cross-counter flow heat recovery ventilator core as they are also known, are an extremely effective and low-cost way of reducing the heating or cooling loads on the treatment of process air and air conditioning systems. A reduced heating or cooling load means lower energy bills and carbon emissions.Air Plates use the exhaust air to pre-heat or pre-cool the in-coming supply air,without the two air streams ever mixing.
Working principle:
Cross-counter flow is higher efficiency energy recoverer,part of two air sreams cross flow, and part of counter flow, combined the cross flow heat exchanger and counter flow heat exchanger two ways heat transfer, realized the energy recovery of exhaust air.
************************************************************************************************************
If you are insteresting in cross-counter flow heat recovery ventilator core,click here to contact with Jenny Yang.
************************************************************************************************************
Features of Cross-counter flow heat recovery ventilator core
1. Aluminum foils cross flow sensible heat exchanger
2. Heat recovery efficiency up to 75%
3. 2-side press shaping, double folded edge.
4. Resistance of pressure difference up to 2500Pa
5. Under pressure of 700Pa, air leakage less than 0.6%
INSTALLATION NOTES
Condensing water pan
When designing heat recovery functional section in air handling unit, under the heat exchanger should add the condensing water pan, in case of disorderly flow of condensing water
Heat exchanger vertical installation
When outdoor temperature is lower than indoor temperature, during heat exchanging if RA temperature is low enough (relative humidity 100%) then condensing water will come into
being, once there is condensing water, heat exchange area inside heat exchanger is decreased, efficiency become lower and pressure drop increased, in order to eliminate the condensing
water in time, heat exchanger vertical installation like the picture below is the best choice.
Installation
Pattern 1 and 2, to increase the heat exchange area, suitable for occasions requiring higher heat recovery efficiency,
however, air resistance will increase accordingly.
Pattern 3 and 4, to increase the front face area, suitable for occasions requiring large airflow, both air resistance and
heat recovery efficiency remain stable.
Pattern 5, to increase both front face area and heat exchange area, suitable occasions requiring higher heat recovery
efficiency and large airflow.
Applications
Installed in air handling unit
AIR-ERV plate heat exchanger can be used in the air handling unit (AHU) as a main part of the heat recovery section, and the bypass can be built in when required.
************************************************************************************************************
If you are insteresting in cross-counter flow heat recovery ventilator core,click here to contact with Jenny Yang.
************************************************************************************************************
Installed in ducts
It can also be installed in the ducts of ventilation system as a main part of the heat recovery section. The installation is very flexible.
AIRERV Factory
AIRERV is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 1996, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Daikin,Shenling, etc.
AIRERV partner
AIR-ERV cooperate with world famous brand or offer OEM service including Midea,Shenling,Daikin, etc.
AIRERV certificate
AIR-ERV products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, Eurovent, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.
What's the difference between sensible heat exchanger and total heat exchanger?
1.Sensible heat exchanger is made of Aluminium foil,total heat exchanger is made of paper.
2.Sensible heat exchanger only exchange heat,total heat exchanger can exchange both heat and humidity.
3.Sensible heat exchanger has longer life and higher pressure-resistance than total total exchanger.
Because the paper heat exchanger are easy to be corroded by the water and dust in the air.The vent of
total heat exchanger is easy to be blocked and hard to be cleaned.This will lead to bad ventilated effect.
1. AIR-ERV can supply OEM service for customers.
2. Produce ERV/HRV, heat exchanger according to customer's special demands.
3. Supply spare parts according to order quantity.
4. General testing and operational test carried out for every units before delivery.
5. Long warranty period.
Welcome to our cross-counter flow heat recovery ventilator core .