Promag D, the wafer device is designed for all applications where space is at a minimum. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10D offers accurate measurement of liquids for a wide range of applications. It will be the preferred solution for customers in the water industry aiming for minimized cost of ownership. Promag 10D is available in a compact or remote version.
Benefits
Easy, fast centering of the sensor – innovative housing construction
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Cost-effective – designed for easy applications and direct integration
Safe operation – display provides easy readable process information
Fully industry compliant – IEC/EN/NAMUR
Maintenance-free – no moving parts
Field of application
The measuring principle is virtually independent of pressure, density, temperature and viscosity
For basic water applications; optimized for limited space and plastic pipe installations.
Device properties
Short installation length and low weight
Integrated ground disks made of stainless steel
International drinking water approvals
2-line display with push buttons
Device in compact or remote version
HART
Technical information
Measuring Principle | Electromagnetic | |
Product headline | The highly cost-effective flowmeter designed as compact wafer version. For basic water applications; optimized for limited space and plastic pipe installations. | |
Sensor features | Easy, fast centering of the sensor - innovative housing construction. Energy-saving flow measurement – no pressure loss due to cross-section constriction. Maintenance-free -no moving parts. Short installation length and low weight. Integrated ground disks made of stainless steel. | |
Transmitter features | Cost-effective – designed for easy applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line display with push buttons. Device in compact or remote version. | |
Nominal diameter range | DN 25…100 1"…4" | |
Max. measured error | ±0.5% | |
Measuring range | 0...600 m3/h | |
Max. process pressure | PN16 Cl 150 JIS 10K | |
Medium temperature range | 0...+60°C (+32...+140°F) | |
Degree of protection | IP 67 (Nema 4x) | |
Display/Operation | Two line display Push buttons | |
Outputs | 4...20mA + pulse,-/status (configurable) | |
Digital communication | HART | |
Hazardous area approvals | FM CSA |