Super Ozone Indicator
Negotiable /Unit
Min.Order:10 Units
Tongdy Sensing Technology Corporation (Beijing)
Super Ozone Indicator
u Real time detect ozone in wall mounting type
u Semiconductor ozone gas sensor inside and measuring range 10~500ppb.
u More than 5 years lifetime.
u Special temperature compensation design for ozone measurements
u Design an easy zero-calibration way
u Full time indicates ozone levels with special design 6 indicator lights
u Six different ozone range corresponds with different lights indicating.
u The on/off output option for control an ozone generator
u Four setting ozone level ranges can be selectable to control the relay output via jumpers
u Optional one analog output for ozone measurement
u Modbus RS-485 interface with 15KV antistatic protection, independent address setting.
Specifications
Gas detected | Ozone |
Sensing element | Semiconductor ozone gas sensor |
Power Supply | 24VAC/VDC±10% |
Consumption | 2.2 W |
Temperature sensor | NTC 5K |
Warm up time | 96 hours (first time) 1 hour(operation) |
Signal Update | 2s |
O3 Measuring Range | 10~500ppb |
O3 measuring precision | ±15ppb + 20% reading (10~50°C/30~70%RH) |
Six indicator lights | The first green indicator light:O3≤49ppb The first and the second green indicator lights:50ppb~99ppb The first yellow indicator light:100ppb~199ppb The first and the second yellow indicator lights:200ppb~299ppb The first red indicator light:300ppb~399ppb The first and the second indicator lights:O3 ≥400ppb |
Modbus interface | Modbus RS485 protocol with19200bps(default), 15KV antistatic protection, independent base address, 31 max network nodes |
Relay output(optional) | One dry contact output, rated switching current 2A(resistance load). Provide four ozone ranges to be selected to control the relay turn-on/turn-off (50ppb /100ppb-default / 200ppb/ 300ppb) |
Analog output(optional) | 1X0~10VDC or 4~20mA for ozone measurements |
Operation temperature | 0~50°C (32~122°F) |
Operation humidity | 5~95%RH,non condensing |
Storage conditions | 10~50°C (50~122°F) |
Weight | 190g |
Dimensions | 100mm×80mm×28mm |
Installation standard | 65mm×65mm or 2”×4” wire box |
Housing/ IP rate | PC/ABS plastic fireproof material, IP30 |
Standard | CE-Approval EN60730-1:2000 +A1:2004 + A16:2007 + A2:2008 Directive: 2004/108/EC |
Models
ITEM | MODEL | DESCRIPTION |
Ozone Detector/Controller | F2000TSM-O3-L100C | Ozone indicator with 6 LED indicator lights Modbus RS485 interface |
F2000TSM-O3-L101C | Ozone indicator with 6 LED indicator lights One dry contact output, Modbus RS485 interface | |
F2000TSM-O3-L110C | Ozone indicator with 6 LED indicator lights One analog output, Modbus RS485 interface |