wall mounting Indoor Air Quality carbon dioxide CO2 Controller/monitors with temp &%RH
USD $50 - $150 /Piece
Min.Order:10 Pieces
Tongdy Sensing Technology Corporation (Beijing)
wall mounting Indoor Air Quality carbon dioxide CO2 Controller/monitors with temperature and humidity
Indoor Air Quality carbon dioxide CO2 Controller/monitors Descriptions:
1.The monitor/controlleris special design to monitor and alarm CO2 level, also provides upto one 0~10VDC output and one on/off relay output to control a fan or a CO2generator.
2.An data logger is designed inside, which canrecord CO2 measurements more than 115 days and can be saved the datavia a USB disk.
3.Thememorial CO2 monitor/controller not only very easily to be used as aCO2 monitor and controller, but also as a recorder of themeasurements.
F2000IAQ-CO2-31XXUseries Application in schools, kindergartens, officebuildings, greenhouses and so on.
Carbon dioxide CO2 Controller/Monitors Features
1.Real-time monitoringcarbon dioxide (CO2) measurements during 0ppm to 20,000ppm range
2.Optional real-timemonitoring temperaturefrom -20°Cto 60°C and relative humidity from 0 to 100%RH
3.Non-dispersiveinfrared (NDIR) CO2 sensor withself calibration, 15 years lifetime
4.The 3-LED indicatorlights indicate three CO2 measured ranges
5.LED lights brightnessadjustable
6. Provide1X0~10VDC output for alternative linear CO2measurement and PID control output
7.Provide1X On/Off dry contact output to control alternative a ventilator and a CO2generator
8.An internal data logger is used torecord CO2measurementsas well as optional temperature and RH% measurements.
9.With super large capabilitymemorizer, it can save data of up to 115 days
10.Provide the software to preset thesampling time, read and record CO2/temperature&RH levels on PC
11.Post the data from the internalmemorizer by any USB disk, and copy the data to a PC
Carbon dioxide CO2 Controller/monitors Features Specifications
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Depressive Infrared Detector (NDIR) |
Temperature sensor | NTC |
Temperature correction | Self compensation |
CO2 NDIR life | 15 years |
Consumption | 3.5W/ Max, 2.5W/ Average |
Accuracy@25°C(77°F) | ±40ppm + 3% of reading |
Stability | <2% of FS over life of sensor (15 yr typical) |
Warm up time | 2 hours (first time) 2 minutes (operation) |
CO2 measuring range | 0~2000ppm, which is default value 0~(1,000~20,000)ppm, programmable selection |
CO2 setting & Display resolution | 1ppm |
Temperature measuring range | 0~50°C(32~122°F) |
Temperature setting range | 5~45°C(41~113°F) |
Option: 1X dry contact output | Rated currency for contact point: 3A 220VAC/30VDC, resistance load |
Option: RS485 communication interface | 9600/14400/19200(default)/28800/38400bps rates selectable by program,15KV protection for static, independent address setting |
Operation condition | 0~50°C (32~122°F), 0~95%RH without condensing |
Power supply | 220VAC/110VAC or 24VAC 50/60HZ±10% |
Weight | 380g |
Dimensions | 130mm×90mm×40mm |
Connections Interface | Locate in interface of connection |
Installment standard | 65mm×65mm or 2”×4” wire box |
Wiring standard | Wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Programming and selection | DIP switches inside and external push-buttons |
Shipping Information
India. Ctn. Dim | 135mm×95mm×55mm |
Master Ctn. Qty | 40 |
Master Ctn. Dim | 44cm(L)×32cm(W)×32cm(H) |
Master Ctn. Wt. | 15 KG |
Model Guide
Gas Type |
|
CO2 | Carbon Dioxide |
Code | Model | |
3 | 1 | Standard model (CO2 &temperature detection) |
5 | 1 | CO2 &temperature detection with RS-485 network communication |
Code | Analog output |
0 | No analog output |
1 | 1X 0~10V output |
Code | Dry contact output |
0 | No dry contact output |
1 | 1X dry contact output |
Code | Humidity option |
RH | Relative humidity detection |
Code | Power supply |
A | 220/240VAC |
B | 100/120VAC |
C | 24VAC |
F2000IAQ | CO2 | — | X1 | 1 | X2 | X3 | — | Y1 | — | Y2 |
Note: X2 + X3 ≤1
Example: F2000IAQ-CO2-3100 indicates that it is a CO2 indicator with temperature detection.