plug and play type CO2 sensor for greenhouse
USD $1 - $2 /Piece
Min.Order:10 Pieces
Tongdy Sensing Technology Corporation (Beijing)
Plug and play type CO2 sensor for greenhouse
CO2 sensor Features
Special used to real-time detect CO2 level in airducts.
NDIR infrared CO2 sensor inside withSelf-Calibration and up to 15 years lifetime
High accuracy humidity and temperature detection&displayoptional
With LCD or without LCD selectable
Providing one dry contact output with presetting thesetpoint
Modbus RS485 communication interface optional
Wireless of ZigBee protocol optional
Smart structure with easier wire connection through theexternal pipe
Provide four types: wall mounted, duct mounted, splitand plug & play
For plug & play type, special design a photosensorinside to detect
day/night and change theworking mode of the CO2 generator
For duct probe type, special the 180° rotatable fastnessposition of the
probe can be used in two directionsof air flow.
Replaceable filter in the probe and extendable probe length
Design the convenient and easier buttons for operation
CE-Approval
Wall mounted with plug & play
CO2 sensor Typical Applications
In office andresidence areas to detect CO2 level
Ventilationcontrol
In BAS todetect the CO2 and the data transmittance
For greenhouseand plant bin
For CO2laboratory
Specifications
CO2 Sensor | Non-Dispersive Infrared Detector (NDIR) | |
Measurement Range | 0~2,000ppm (default) 0~5,000ppm (preset) | |
Accuracy | ±40ppm + 3% of reading @22°C(72°F) | |
Stability | <2% of full scale over the life of the sensor | |
Calibration | Self-calibration system | |
Response Time | <5 minutes for 90% step change at low duct speed | |
Non-linearity | <1% of full scale @22°C(72°F) | |
Duct Air Velocity | 0~450m/min | |
Pressure Dependence | 0.135% of reading per mm Hg | |
Warm up time | 2 hours (first time) 2 minutes (operation) | |
Split CO2 sensor | 2 meter cable connection between the senor and the controller | |
Temperature & Humidity Detection&Display (optional) | Temperature | Relative Humidity |
Sensing element: | Band-gap-senor | Capacitive humidity sensor |
Measuring range | -20°C~60°C | 0 -100%RH |
Accuracy | ±0.5°C (20~40°C) | ±4.5%RH (25°C, 15%-85%RH) |
Display resolution | 0.1°C | 0.1%RH |
Stability | ±0.1°Cper year | ±1%RH per year |
General Data |
| |
Power supply | 24VAC/24VDC or 100VAC~240VAC | |
Consumption | 1.8 W max. ; 1.0 W avg. | |
LCD display | Display CO2 measurement or CO2 + temperature& humidity measurements | |
Dry contact output (optional) | 1xdry contact output for CO2 Max. 5A (100~240VAC/30VDC)rated switch contact | |
Plug& play type | Just for 100VAC~240VAC power supply with European or American power plug and power connector to the CO2 generator | |
Modbus RS485 Interface (optional) | 19200bps, 15KV antistatic protection. | |
Wireless module (optional) | ZigBee 2.4G short distance wireless communication | |
Operation conditions | -0°C~50°C(32~122°F); 0~99%RH, non condensing | |
Storage conditions | 10~50°C(-40~158°F)/ 20~60%RH | |
Net weight | 280g | |
IP class | IP30 | |
Standard Approval | CE-Approval |
Typical Applications
u In office and residence areas to detect CO2 level
u Ventilation control
u In BAS to detect the CO2 and the data transmittance
u For greenhouse and plant bin
u For CO2 laboratory