CO2 Indicator / Alert

CO2 Indicator / Alert

Negotiable /Piece

Min.Order:50 Pieces

Supply Ability:
1000 Piece / Pieces per Month
Port:
Beijing

Quick Details View All >

Place of Origin:
Beijing, China
Brand Name:
Tongdy
Model Number:
F2000IAQ-CO2-31XX/51XX

Tongdy Sensing Technology Corporation (Beijing)

Business Type: Manufacturer,Trading Company
Beijing China
Main Products: CO2 sensor ,CO2 controller ,CO detector ,Ozone controller ,Digital thermostat

Product Details

Gas detected

Carbon Dioxide (CO2)

Sensing element

Non-Dispersive Infrared Detector (NDIR)

Temperature sensor

NTC

Humidity sensor

HS series capacitive sensor

Temperature dependence

0.2% FS/°C

Temperature correction

Self compensation

Power supply

24VAC/VDC, or 100~240VAC, 60HZ, selectable with the order

Consumption

3.5 W max. ; 2.5 W avg.

Accuracy@25°C(77°F)

±30ppm + 3% of reading

Stability

<2% of FS over life of sensor (15 yr typical)

Calibration interval

ABC Logic Self Calibration Algorithm

Non linearity

<1% of FS

Pressure dependence

0.13% of reading per mm Hg

Altitude calibration

Programmable from 0-9,900m in 100m increments

Response Time

<2 minutes for 90% step change

Signal update

Every 2 seconds

Warm up time

2 hours (first time)

2 minutes (operation)

CO2 measuring range

0~2,000ppm (default)

0~20,000ppm, programmable selection

0~50,000ppmt

CO2 setting & Display resolution

1ppm

Temperature measuring/ setting range

0~50°C(32~122°F)/ 5~45°C(41~113°F)

 

 

 

 

Humidity measuring/setting range

0~99%RH/ 5~95%RH

Analog output

0~10VDC linearized output or PID control output, selectable by end users

Output resolution

10Bit

Relay output

One or two dry contact outputs with programmable selection to control CO2, temperature, humidity

Rated switching current: 3A(220VAC/30VDC), resistance load

Communication interface

RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64

Flow rates

Diffusion version 80 ~ 120 cc/min

Flow through version 40~50cc/min

Operation conditions

0~50°C(32~122°F); 0~95%RH,

Storage conditions

-10~60°C(14~148°F)/5~90%RH non condensing

NDIR life

15 years

Weight

360g

Dimensions

130mm×90mm×40mm

Installment standard

65mm×65mm or 2”×4”wire box

Interface connections

Maxi. 9 terminals

Wiring standard

wire section area<1.5mm2

Approval Standard

CE-Approval

Programming and selection

Via internal jumpers and push-buttons on the panel

 

1) Special design for room CO2 indicator and alarm. For example in classrooms, offices and other public places 

2) Real-time detecting and display CO2 level during 0ppm to 20,000ppm CO2 range; Also detecting room temperature from 5 to 65

3) Optional real-time humidity from 5%RH to 95%RH

4) NDIR CO2 sensor technology of infrared self diffusion, 15 years lifetime

5) Self Calibration Algorithm makes it in using without calibration amending

6) Specially provide the altitude calibration

7) The three measured CO2 ranges for 3-LED indicator lights are set by end users

8) 3 LEDs brightness adjustable

9) Optional 1X dry contact output to control a ventilation device

10) Optional 1x0~10VDC output

11) Optional the buzzer alert for CO2 level

12) Optional RS485 interface to connect to a PC or another system

Contact Supplier

Ms. Qing Tian director Chat Now
Telephone
86-10-59738930-8075
Mobile
15811018575
Fax
86-10-59738935
Address
8# Building, #9 Courtyard Dijin Rd. Haidian district Beijing