An Ying electronic power and auto testing machine for detecting underground water pipline leakage, ultrasonic leak detector.
Product Description
The information of each part
- Handle host connector should be into the host signal input interface(It will not be able to open equipment power supply if no connection.It is the function set up for operator to prevent to forgot to shut off the power specially)
- The sensor connector of the handle should be insert into the corresponding interface of the sensor vibration picking/span>
- Insert earphone plug into the output interface of host audio.
Malfunctions and troubleshooting measures
Fault Phenomenon | Reason | Ruled out measures |
Instrument can't boot up | 1.Host and handle cable is not connected 2.The battery without electricity | 1.The host connected to the controller cable should be reliable. 2.Charging battery or Replace new battery. |
Article no dynamic light show on the screen,No Voice in Earphone | 1.Connection between the sensor and controller cable vibration picking is unreliable 2.Display series, volume series setting may be too small. | 1.Check if connector connection is reliable 2.Set the appropriate volume display series, series. |
With dynamic light show on the screen,headphones are silent | 1.The switch on the handle may be forget to press 2.The headset poor contact | Check the handle and headphones. |
Headphones in whistler | The distance between sensors and vibration picking headset is too close | Don't close to the sensor vibration picking to headphones.Decrease the display series and the volume series at the same time |
Starting up automatically and power off within a short time Part of the button doesn't work,When the battery icon is displayed for the blank | The battery voltage is low | Battery charging in time or replace new battery |
Occurs crash failures when playback | Didn't record the full 1 minutes and quit when recording the segment content | Press(reset)button to make the instrument back to normal |
Stationary screen picture or No pictures showed,but the handle on the lights is still bright,Press any button no response | Mistake operation | Press(reset)button to make the instrument back to normal |
Matters need attention
- The instrument should be avoided unwarranted crash, scratch, tensile cables, etc, although the instrument design is considering the tolerance of outdoor operation.
- Pay special attention to vibration sensor is not high in the fall, instrument surface should not be under pressure, do not force a touch screen, so as not to cause damage of equipment.
- Do not force shaking probe
- Do not remove the instrument itself
- Special packing is equipped with positioning gasket.The parts must be placed in position when packing. Parts are smooth to avoid stress when close the box.
- Pay attention to clean, no corrosion, and avoid moisture in high temperature when stored.